11
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
Please note: This documentation may contain further technical data.
11.1
Features
ICD890-x523xxxx
ICD890-x434xxxx
Function
Line-scan camera with integrated 1D / 2D code decoder, image output, and further optional 2D
vision functionality
Focus
Dynamic focus control or fixed focus
Sensor
CMOS line sensor
Type: High resolution
CMOS line sensor
Type: Standard resolution
Line frequency (scan‐
ning rate)
Max. 43 kHz
Max. 50 kHz
Code resolution
≥
0.1 mm
Working range
1,550 mm ... 3,900 mm
1)
1,550 mm ... 3,600 mm
1)
Field of view
Covered conveyor width 1 800 mm at 170 dpi
resolution
Covered conveyor width 1 560 mm at 200 dpi
resolution
Conveyor width: 1,200 mm at 170 dpi resolution
Conveyor width: 1,035 mm at 200 dpi resolution
Operating mode
Forward, Backward, Start/Stop
Lens
Integrated
Focal length: 120 mm
Integrated
Focal length: 95 mm
2D Vision functional‐
ity
2)
•
Extended analysis of code quality
•
empty tote detection
•
hazardous material detection
•
object classification
•
2D dimensioning (image-based calculation of object dimensions)
1)
Relative to the device reference point,
see "Field of view diagrams", page 39
2)
For further 2D Vision functions, contact SICK Sales. To find your agency, see the final page of this document.
TECHNICAL DATA
11
8023775/18IM/2020-07-02 | SICK
T E C H N I C A L I N F O R M A T I O N | Camera ICD890 Generation 4
35