0 = The corresponding error, warning or event is not active.
Bit 0
SUM0
: Status summary bit (interface)
1 = An error, a warning or an event associated with the DSL Slave protocol interface
was triggered.
0 = The DSL Slave protocol has not triggered an error, warning or event.
NOTE
A bit that has been set in summary register is not automatically deleted by the DSL Sys‐
tem. To delete, the user application must read the corresponding DSL Slave encoder
status register and acknowledge the status message, by individually deleting each set
bit.
6.3.15
Safe position
The value for each safe position transmitted is compared with the incrementally gener‐
ated position value (fast position) (see registers 10h to 14h).
The safe position is not synchronized with the
sync
signal.
Only those
vpos
bits are activated that lie within the range that the motor feedback
system has actually measured. All other higher value bits are read as "0". The number
of measurable bits can be taken from
ENC_ID
bits 9 to 0 in the
ENC_ID0 to 2
regis‐
ters.
If
Sign
is set in the
ENC_ID
register, the value of the safe position is given signed in the
two's complement.
The units of the position value are [steps]. These registers are write protected.
Register 19h:
Safe position, byte 4
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
Safe position, byte 4
Bit 39
Bit 32
Register 1Ah:
Safe position, byte 3
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
Safe position, byte 3
Bit 31
Bit 24
Register 1Bh:
Safe position, byte 2
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
Safe position, byte 2
Bit 23
Bit 16
Register 1Ch:
Safe position, byte 1
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
Safe position, byte 1
Bit 15
Bit 8
Register 1Dh:
Safe position, byte 0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
Safe position, byte 0
REGISTER MAP
6
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
47