Table 95: Reading the rotation speed
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
54
C7
00
00
01
Wait for FREL = 1
Read
Rotation
speed
8.5.9
Acceleration range
This resource indicates the permitted minimum and maximum shaft acceleration for
rotary DSL motor feedback systems given in the product data sheet.
Direct read access to acceleration range returns the defining values:
Table 96: Acceleration range defining values
Defining value
Offset
Value
RID
0C8h
Resource name
0
"ACCRANGE"
Data size
1
2
Read access level
2
0
Write access level
3
15
Time overrun
4
70
Data type
5
04h – 16 Bit, unsigned
Mandatory
no
The value of the acceleration range is stored as an unsigned 16 bit value. The accelera‐
tion value units are 1000 rad/s².
It should be noted that the current acceleration value can be derived from the rotation
speed process value in the "process data channel" (see
The acceleration range value is given in the following format:
Table 97: Acceleration range definition
Byte
Value
Description
1/0
0 to 65535
Maximum permitted rotational acceleration of the
encoder in 1000 rad/s²
For this resource, access to the offset basis is not meaningful as the resource data can
be read using a "long message" transaction.
Table 98: Reading the acceleration range.
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
54
C8
00
00
01
Wait for FREL = 1
8
MOTOR FEEDBACK SYSTEM RESOURCES
106
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
8017595/ZTW6/2018-01-15 | SICK
Subject to change without notice