Keep open (= unshielded) wire lengths as short as possible, especially for the data
wires (<20 mm)
•
Keep data wires well separated from power and brake wires, no wire crossing
•
The shielding of the data lines needs to be separated from the other shielding
•
no pigtails for any shielding connection
•
A motor connector type coupling shall be used instead of terminal boxes.
10.3.3
Connector to motor
Up to some extent the motor [power] size defines the type [size] of connector used for
motor connection to the hybrid cable. Currently two different sizes are in use: M17 and
M23, the last one is the mainly used size. The M17 connector size is used for very
small motors only (typical frame size 55 mm and smaller). For both the connector sizes
there are the same requirements applicable:
•
Keep open (= unshielded) wire lengths as short as possible, especially for the data
wires (<20 mm)
•
Keep data wires well separated from power and brake wires, no cross overs
between data and other wires
•
Connect the shielding via areal contact to the connector (no pigtails)
•
Data line shielding gets its own contact through the connector. For connecting and
assembling of the particular connector follow the according instructions of the
manufacturer. For interchangeable components (motor/cable) the pin layout as
shown at the figure below shall be used (9-pin-M23 size motor connector).
Figure 43: Pin layout M23
Pin layout for a M23 size motor connector. Main & brake line shielding is connected
together to the connector housing; within the connector also PE is connected to the
connector housing; there is a separate feedthrough of the data line shielding. When
using a shielded configured encoder connecting set the shielding of this set is con‐
nected to the according pin on the motor part of the connector.
10.3.4
Verification
Within [HIPERFACE DSL field test & analysis – Possibilities and limits Application Note
Vers. 12-00; Doc. E_148498] there are tests listed to check the performance of the
connection line, especially during field inspection. These tests are also applicable to
check and verify a system configuration initially. Signal transmission performance:
•
Evaluation of the contents for registers RSSI, EDGE, DELAY, QM.
•
Monitor the digital IP-core output signals
estimator_on
and
encoding_err
•
Monitor the online_status_d register bit for POS, DTE and QMLW
DSL COMPONENT INTEROPERABILITY
10
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
167