3.4
Cable installation (general information)
3.4.1
Using suitable cables
▸
The mains cable must comply with standard IEC 60227 or IEC 60245.
▸
Only use cables approved for use in the potentially explosive atmosphere involved.
▸
Only use cables with suitable outer diameters (
).
▸
Fit connected cables fixed, i.e. fasten cables along the whole length.
3.4.2
Closing off cable inlets correctly
▸
Seal all cable inlets “vapor-proof” (almost gas-tight) before start-up.
▸
Only open those cable inlets to be used for installing cables. Keep the plugs. Refit the
original plug when a cable inlet must be closed again afterwards.
Table 1
Cable diameters
Device component
Cable inlets
Suitable for cables with
outer diameter
Mains switch/mains connection
All
7 … 12 mm
[1]
[1] Further technical requirements on the mains cable
Interface box
Small version
5 … 10 mm
Large version
6 … 12 mm
The cable inlets are sealed when delivered.
The cable inlets are part of the approval.
▸
Do not replace cable inlets with a different type of cable inlet.