1
2
3
4
Figure 24: Detail view: Positioning the top mounting
ring on the side of the purge air fixture
1
Installation plate
2
Top mounting ring
3
Bottom mounting ring
4
Detail view: Positioning the top mounting ring
on the side of the purge air fixture.
2
Place the weatherproof cover on the installation plate:
b
Position the cover on the installation plate from the top.
b
Engage the locks and close again.
Figure 25: Placing the weatherproof cover on the
installation plate
7.14
Preset parameter values
Parameter settings
Physical unit
mg/Nm
3
Normalization
wet
Response time
24 s (parameter setting)
Note: The actual total response time is 30
s
because the preset value (11) of the Median filter
extends the response time by 6 s.
Measuring range
1000 mg/Nm
3
Limit value
1000 mg/Nm
3
COMMISSIONING
7
8008932/16YT/V4-0/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | GM901-02
49