Assembly and Installation
FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
87
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
Determining the nozzle position and marking on the pipeline for cross-duct types
FLSE100-EXS and EX/EXRE
Fig. 36
Determining the nozzle positions on the strip
1-path measurement
2-path measurement
5) Draw guide lines (1) for the nozzle positions in a distance as listed in the table, mark the crossing points (2) and draw marking points
(3) in distance 60 mm (x) from the crossing points.
Overlap line U/2 Kink line
90 ° 90 °
4a) Roll the strip out again and mark the kink line.
90 ° 90 ° 90 ° 90 ° 90 °
4b) Roll the strip out again and mark the lines as follows:
2.498•r 2.498•r
0.6435•r 0.6435•r
r = D/2
(
6a )Measure and note values a and U/2 (needed to calculate
the path angle and path length).
Outside
diameter
Nozzle offset a
FLSE100-EXS
FLSE100-EX/EXRE
inch
mm
mm
inch
mm
inch
4
114
32.0
1.25
5
141
37.5
1.48
6
168
44.0
1.72
8
219
55.0
2.17
50.0
1.94
10
273
67.0
2.64
61.5
2.42
12
324
78.5
3.08
72.5
2.86
14
356
85.5
3.36
79.5
3.14
16
406
96.5
3.80
91.0
3.58
18
457
108.0
4.24
102.5
4.03
20
508
119.0
4.68
113.5
4.47
22
559
130.5
5.13
125.0
4.91
24
610
141.5
5.57
136.0
5.35
26
660
147.5
5.80
28
711
158.5
6.24
30
762
170.0
6.68
32
813
182.0
7.13
34
864
192.5
7.57
36
914
203.5
8.02
42
1067
237.5
7.35
48
1219
271.0
10.68
x
x
x x
U/21
a
2 3
x
x
x x
a
Outside
diameter
Nozzle offset a
FLSE100-EXS
FLSE100-EX/EXRE
inch
mm
mm
inch
mm
inch
12
305
64.0
2.52
58.0
2.30
14
356
70.0
2.76
64.0
2.51
16
406
79.0
3.11
73.0
2.87
18
457
88.0
3.46
82.0
3.22
20
508
97.0
3.82
91.0
3.58
22
559
106.0
4.17
100.0
3.93
24
610
115.0
4.53
109.0
4.29
26
660
118.0
4.64
28
711
127.0
5.00
30
762
136.0
5.35
32
813
145.0
5.71
34
864
154.0
6.06
36
914
163.0
6.42
42
1067
190.0
7.48
48
1219
217.0
8.54
52
1321
235.0
9.25
56
1422
253.0
9.96
60
1524
271.0
10.67
64
1626
289.0
11.38
68
1727
307.5
12.10
72
1829
325.0
12.80
U
1
2 3
Path 1Path 2
6b) Measure and note values a and U (needed to calculate the
path angle and path length).