Start-up and Parameter Settings
FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
193
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
4.3.4
Entering process parameters
Further process parameters must be entered to calculate mass flow, molecular weight and
gas density.
Select device file "MCU-P", enter the Level 1 password and set the measuring system to
"Maintenance" mode (
).
Select the "Parameter / Measuring Point 1(2/3) / Process Values" directory.
Select the algorithm for measured value computation (
).
If necessary, correct the constant values entered at the factory for the process parame-
ters:
– When using the basic algorithm:
Viscosity, compressibility, adiabatic coefficient
– When using the MR-113-03 algorithm:
Gas composition values
– When using the Hydrocarbon algorithm:
Viscosity, compressibility
Fig. 129
"Parameter / Measuring Point 1 / Process Values" directory