Terminal data
n.c.: normal closed
n.o. normal open
●
Terminal assignment interface modules
Fig. 75
Interface module terminal assignment
Terminal
Module type
2x Analog
input
2x Analog
output
2x Digital
input
Digital output
2 changeover contacts
Assignment
11
AI 1+
AO 1+
DI 1+
n.c. relay 1
12
AI 1-
AO 1-
gnd
com. relay 1
13
AI 2-
AO 2-
gnd
com. relay 2
14
shield (gnd)
shield (gnd)
DI 3+
n.c. relay 2
21
AI 2+
AO 2+
DI 2+
n.o. relay 1
22
AI 1-
AO 1-
gnd
com. rel. 1
23
AI 2-
AO 2-
gnd
com. rel. 2
24
shield (gnd)
shield (gnd)
DI 4+
n.o. relay 2
Rating
max. voltage
3 V d.c.
15 V d.c.
5.5 V d.c.
30 V a.c./d.c.
max. current
22 mA
22 mA
5 mA
2 A
Interface module
Interface module
Interface module
Et Impulse
Impulse
HART® Bus
> 250 Ohm
→
P
LC input
– +
gnd gnd pulse
– +
gnd gnd pulse
– +
gnd gnd pulse
Tx
Interface
module
Power
not
not
used
used
HART
part no. : 2050607
part no. : 2050607
& ImpulsOut
gnd
-
+
4..20 mA
MCU
Rx
Impuls
gnd
gnd
gnd
gal.