6.2
System connection (M12, 5-pin)
1
2
3
4
5
Figure 35: System connection (male connector, M12, 5-pin)
Table 13: System connection pin assignment for SP1 and SP2 (M12 male connector, 5-pin)
Pin
Wire color
1)
Active unit
1
Brown
+24 V DC (voltage supply input)
2
White
OSSD1 (output signal switching device 1)
3
Blue
0 V DC (voltage supply input)
4
Black
OSSD2 (switching output 2)
5
Gray
Not assigned
1)
Applies to the connecting cables recommended as accessories.
6.3
System connection (M12, 8-pin)
8
2
3
4
5
7
1
6
Figure 36: System connection (male connector M12, 8-pin)
Table 14: System connection pin assignment for SP1 (M12 male connector, 8-pin)
Pin
Wire color
1)
Active unit
1
White
In3
RES (reset pushbutton input)
2
Brown
+24 V DC (voltage supply input)
3
Green
MFP3
ADO (application diagnostic output)
4
Yellow
In4
EDM (external device monitoring input)
5
Gray
OSSD1 (output signal switching device 1)
6
Pink
OSSD2 (switching output 2)
7
Blue
0 V DC (voltage supply input)
8
Red
Not assigned
1)
Applies to the connecting cables recommended as accessories.
Table 15: System connection pin assignment for SP2 (M12 male connector, 8-pin)
Pin
Wire color
1)
Active unit
1
White
In3
RES (reset pushbutton input) or override
(override input)
2
Brown
+24 V DC (voltage supply input)
3
Green
MFP3
ADO (application diagnostic output)
6
ELECTRICAL INSTALLATION
62
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
8024782/2019-11-19 | SICK
Subject to change without notice