mounting
method
Description
On the back
Fasten the M5 screw to the machine or profile frame through the QuickFix
bracket. A screw nut or threaded hole is required on the machine or profile
frame (
$
).
1)
If the bracket is attached at the side, no muting arms can be mounted on the protective device.
!
§
$
"
a
b
a
b
Figure 29: Mounting the QuickFix bracket on a profile
1
Mounting on the side
2
Mounting on the side
3
Mounting on the side
4
Mounting on the back
5.4.2
Mounting the FlexFix bracket
Overview
In the FlexFix bracket, the active and passive units can be rotated ± 15°
2)
around their
longitudinal axis.
The active and passive units are each mounted using 2 FlexFix brackets.
As a rule, each FlexFix bracket is mounted to the mounting surface with 2 screws. In
exceptional cases (e.g. reduced vibration and shock requirements), a FlexFix bracket
can be mounted with only one screw if this does not impair the function.
2)
If muting arms are attached to the active and passive units, the units can be rotated ±5° about their longitudinal axis.
MOUNTING
5
8024782/2019-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
55
Subject to change without notice