7.5
Fine adjustment and further configuration
NOTE
The other settings and the fine adjustment depend on the relevant application situa‐
tion.
User level, parameter download to the device
The user is automatically logged into the device in the “Authorized customer” level and
can change parameters which are immediately transmitted to the device (default set‐
ting).
Configuration via “Quickstart”
The “Quickstart” tab offers an overview of the most important parameters and enables
quick evaluation of code content. Functions such as evaluation window, percentage
evaluation, code configuration, and adjusting tool are available via the Quickstart.
Application wizard
The application wizard (“Wand” icon) supports device configuration both as a stand-
alone device and as a master or as a slave for a master/slave combination based on
the CAN bus.
Evaluation window
The evaluation window shows the code content, the object index, the code type, the
code security, and the device number of the reading device.
Percentage evaluation
The percentage evaluation permanently assesses the quality of the reading. Bar codes
are not assessed. Here, the bar codes must not be subjected to any conveying move‐
ment. The device performs 100 scans in each case and evaluates the reading quality.
The device continuously emits read results every 2 s via the AUX interface, together
with the read diagnostic data. A timer starts when percentage evaluation is called. If a
manual abort is not carried out, the device automatically returns to read mode after
5 min.
Adjusting Tool
The “Adjusting Tool” operating mode supports optimal placing of the center of the scan
line on the object. To do this, the device hides half of the scan line.
Figure 38: Appearance of the scan line in “Adjusting Tool” operating mode
This function is only available under analysis in the “Service” user level.
Code configuration
In the factory default setting, the device decodes the following code types:
7
COMMISSIONING
50
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x
8019588/2017-01-20 | SICK
Subject to change without notice