Stable mounting device
–
Alignment of the device in the x and y axes can be adjusted.
–
The mounting device must be able to bear the weight of the device and con‐
necting cables without shock.
■
Two or three M5 screws for mounting the device
■
Three plastic insulation panes are to be used across from the bracket for heat
insulation in devices with heating.
–
The screw length depends on the wall thickness of the mounting device.
–
The maximum screw in depth in the device is 5 mm from the housing sur‐
face.
5.3.3
Replace the laser warning label
The laser warning information on the device must be written in a language understood
by the operators.
The scope of delivery also includes a set of self-adhesive laser warning labels in Ger‐
man, US English and French.
b
If necessary, replace the English laser warning information prior to commissioning
of the device.
IEC60825-1 Ed.2:2007-03; EN 60825-1
Ed.2:2008-05; Complies with 21CFR 1040.10
except for deviations pursuant to Laser
Notice No.50, dated June 24, 2007
IEC60825-1 Ed.2:2007-03; EN 60825-1
Ed.2:2008-05; Complies with 21CFR 1040.10
except for deviations pursuant to Laser
Notice No.50, dated June 24, 2007
Figure 15: Laser warning labels in various languages
5.4
Mounting location
When selecting the mounting location, the following factors are significant:
b
Basic allocation of the scan line to the bar code
b
Reading distance to the bar code and aperture angle α
b
Angle alignment of the device
b
Avoidance of surface reflections
b
Count direction of the reading angle (position of the bar code along the scan line)
5.4.1
Basic allocation of the scan line to the bar code
The basic allocation of the scan line to the bar code on the object depends on the ver‐
sion of the device (line scanner, grid scanner or line scanner with oscillating mirror).
5
MOUNTING
26
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x
8019588/2017-01-20 | SICK
Subject to change without notice