Online Help
Chapter
2
Barcode Scanner CLV62x
CLV62x
8011967/S345/2008-04-23
©
SICK AG · Division Auto Ident · Germany · All rights reserved
9
2.2.1.1 Object trigger control
Start/Stop of object
trigger
The trigger source is configured with the parameters of the
group.
Fig. 2-1:
Impact of the parameters Start delay and Stop delay on the reading gate.
Parameter
Function
Control
Select type of control (based on time or path via incremental
encoder
chapter 2.2.2 Increment configuration, page 11
).
Start delay
Enter delay between start trigger and the opening of reading gate.
Select possible delay unit.
Select source of start trigger.
From
Enter the CAN address of the device from which the start trigger is
derived.
For this device, "
CAN
" must be selected for the
TRIGGER
DISTRIBU
-
TION
.
Stop delay
Enter delay between start trigger and the closing of reading gate.
Select possible delay unit.
Select source/operation of stop trigger.
OR
Select further source/operation of stop trigger (optional). This
source is linked to the first source by a logical OR.
OR
Select further source/operation of stop trigger (optional). This
source is linked to both previous sources by a logical OR.
Pulse
Enter length of pulse for automatic pulse.
If applicable, select unit.
Pause
Enter pause length between two pulses of the automatic pulse.
If applicable, select unit.
Duration
Enter time/path after which a stop trigger is to be initiated.
If applicable, select unit.
50 ms
100 ms
Start
Sensor 1
Reading
gate