C L V 6 s e r i e s | s i C K
8016144/2013-09-19
Subject to change without notice
1 9
bar code ScannerS
CLV61x
Detailed technical data
features
CLV610 Mid range
CLV612 short range
CLV615 Long range
Variant
can
Fieldbus
Light source
Visible red light (655 nm)
MTBF
40,000 h
Laser class
2 (EN 60825-1 (2008-05), IEC 60825-1 : 2007-03, Ed. 2.0)
Field of view
≤ 50°
scanning frequency
400 Hz ... 1,000 Hz
Code resolution
0.2 mm ... 1 mm
0.1 mm ... 0.2 mm
0.35 mm ... 0.5 mm
reading distance (at code resolution)
60 mm ... 365 mm (1 mm)
43 mm ... 93 mm (0.2 mm)
25 mm ... 330 mm (0.5 mm)
raster height, number of lines, at distance
15 mm, 8, 200 mm
–
Performance
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, UPC / GTIN / EAN,
Interleaved 2 of 5
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 10 (Standard decoder)
1 ... 6 (SMART620)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
1,500
500 (for multiplexer function in CAN operation)
No. of multiple readings
1 ... 99
interfaces
CLV610 Mid range
CLV612 short range
CLV615 Long range
serial (rs-232)
l
function host, aux
data transmission rate 2,400 Baud ... 115 kBaud, AUX: 57.6 kBaud
ethernet
–
l
Protocol –
PROFINET Dual Port (optional
via external connection mod-
ule CDF600-2)
CAN bus
l
function SICK CAN sensor network (Master/Slave, Multiplexer/Server)
data transmission rate 20 kbit/s ... 1 Mbit/s
Protocol CSN (SICK CAN Sensor Network)
PrOFiBUs DP
–
l
, optional via external con-
nection module (CDF600-2)
switching inputs
4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 in CDB620/CDM420)
switching outputs
4 (“Result 1”, “Result 2”, 2 outputs via optional CMC600 in CDB620/CDM420)
reading pulse
Switching inputs, non-powered, serial interface, auto pulse, CAN
Optical indicators
1 RGB LED (multifunctional)
Acoustic indicators
Beeper/buzzer (can be switched off, can be allocated as a result indication function)
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T