MOUNTING
How to mount the weather protection hood on the Bulkscan® LMS111:
1. Put the weather protection hood 190° over the Bulkscan® LMS111.
2. Mount the weather protection hood on the Bulkscan® LMS111 using three M5 × 15
countersunk head screws (included with the delivery of the weather protection hood.
For this purpose you will find on the weather protection hood two holes with 90° coun
-
tersink on the rear and one hole with 90° countersink on the right.
Mounting kits for the weather protection hood
Using the mounting kits for the weather protection hood you can align the Bulkscan®
LMS111 in two planes. The maximum adjustment angle is ±22.5° in both planes.
Weather protection hood
Adjustments
Adjusting screws
Fig. 25: Standard mounting kit (part no. 2046025) for the weather protection hood
The quick-action mounting kit for the weather protection hood permits the quick repla-
cement of the Bulkscan® LMS111, without the need to adjust the new device.
5.4
Removing the sensor
Switch the supply voltage off.
Remove the connection cables.
Unscrew the mounting screws for the Bulkscan® on the mounting bracket and re-
move the sensor.
On final decommissioning, please observe the requirements for environmentally correct
disposal (see "2.5.2 Disposal after final decommissioning“ on page 13).