AFS60 AFM60 EIP WEB operating instructions
21
3.3. Preset warning
The preset function is used to set the encoder to a predefined start position. With the aid
of a Preset Value the endcoder can be set to any position within the measuring range.
The Preset Value can be set in the following manner:
• Using the preset push-button
• Using an acyclic explicit message. During this process the Preset Value is transferred
as an attribute (ID19) of the position sensor object.
• Using the WebServer preset (output assembly 106)
•
Using the PLC preset (output assembly 106)
Note:
Only set a Preset Value when the encoder is at standstill
Warning!
The preset function results in an immediate change in the position value output by the
encoder. This change could cause an unexpected movement that may result in a hazard for
persons or damage to the system or other items.