5.
In the
Navigation
area, click on
Monitoring cases
.
✓
The
Monitoring cases
page opens. On this page, you create the different monitoring
cases for the device (
see "Monitoring cases", page 54
7.6.1
Identification
Overview
On the
Identification
page you enter attributes for the device. The attributes are used to
identify the device or to distinguish between different devices. The attributes appear in
reports and in the diagnostic data.
Device name
If a number of safe multibeam scanners are used in an application or in a project, a
unique device name helps to tell the individual devices apart.
Project name
The project name is used to identify an entire project. The same project name should
be chosen for all devices in the project.
Application name
The application name can be the same for a number of devices in the project.
User name
The user name helps later users to find a contact for the application.
Application image
An image helps to identify the application more quickly. The application image is saved
in the project file on the computer and transmitted to the device. The Safety Designer
supports the following file formats: BMP, GIF, JPG, PNG, TIF.
Description
A description makes it easier to understand an application’s context more quickly.
7.6.2
Fields
Overview
On the
Fields
page, you create field sets and draw the associated protective and warning
fields. You can create one protective field and one warning field for each field set.
In the
Field sets
area, you create the field sets and fields. You can also set the object
resolution and multiple sampling for the selected field, or for all fields under
General field
settings
.
In the
Fields
area, you draw the selected field of a field set using the tools on the tool‐
bar. The drawn protective fields must contain the relevant protective field supplement.
The edge length or the diameter of each field must be at least as large as the selected
object resolution. In addition, the selected multiple sampling as well as the maximum
object speed to be assumed have an influence on the minimum required field dimen‐
sions.
7
CONFIGURATION
50