NOTE
Assign the functions for the digital inputs in the device using a configuration tool, e.g.
the configuration software SOPAS ET.
13.4.8
Wiring the external digital inputs of the device in the CDM420-0006
Device = Lector63x = V2D63xx-xxxxYx (Y = A, B or S)
Device
4
CDM420-0006
PNP sensor
7
V
S
GND
3.32 K
6.64 K
V
in
Out
GND
S6
CMC600
3
Aux
(RS-232)
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17 SGND
8 Shield
39 +24 V*
A
Aux In
B
+24V*
“External
input
C
”
5
SensGND
Trigger sensor
1
8
E.g. photo-electric
switch
6
2
Figure 38: Trigger sensor supplied with power by connection module CDM420-0006
1
Trigger sensor, e.g. for read cycle generation
2
Input voltage V
in
3
The optional CMC600 parameter cloning module is required in the connection module in order to be able to use the
additional external digital inputs and outputs of the device
4
Device
5
Logical “External input” in the device
6
e.g. photoelectric sensor
7
PNP sensor
8
Supply voltage V
S
CDM420-0006
PNP sensor
4
V
S
GND
Out
GND
S6
V
S ext
V
in
CMC600
No
YES
S8 : CMC
ON
OFF
S6 : SGND
17 SGND
8 Shield
39 +24 V*
A
Aux In
B
+24V*
SensGND
Trigger sensor
1
5
2
3
CDM420-0006
V
in
GND
S6
CMC600
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17 SGND
8 Shield
39 +24 V*
A
Aux In
B
+24V*
SensGND
3
1
V
S ext
GND
A
17
2
2
Figure 39: Left: Trigger sensor connected potential-free and supplied with power externally. Right: Alternatively switch,
!
sup‐
plied with power by connection module CDM420-0006 or
"
connected potential-free and supplied with power externally.
Switch setting S3 then as in left figure.
13
ANNEX
94
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount
8018071/16XD/2020-05-06 | SICK
Subject to change without notice