background image

2D Barcode Scanner 

OPI 4002 

 
 
 

 

The OPI 4002 is a 2D barcode scanner that •provides 
wireless communication compliant with IEEE 
802.15.4 between the OPI 4002 and a host system. 

Specifications Manual 

 

 

Summary of Contents for OPI 4002

Page 1: ...2D Barcode Scanner OPI 4002 The OPI 4002 is a 2D barcode scanner that provides wireless communication compliant with IEEE 802 15 4 between the OPI 4002 and a host system Specifications Manual ...

Page 2: ...ts that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental da...

Page 3: ...ery Operating Time and Charging Time 8 5 3 AC Adaptor 9 5 4 Operating Indicators 9 5 4 1 LED Indicator and Buzzer 9 6 Optical Specifications 10 6 1 Imager Scanning 10 7 Technical Specifications 10 7 1 Test Samples 1D Symbologies 11 7 2 Test Samples 2D Symbologies 11 7 3 Print Contrast Signal PCS 12 7 4 Minimum Resolution 12 7 5 Scan Area and Resolution 13 7 5 1 Depth of Field 13 7 6 Pitch Skew and...

Page 4: ... Codes 19 10 4 Default Settings 2 Read Options Trigger Buzzer 20 10 5 Default Settings 3 Other Communication Settings 21 11 Serial Number and Labeling 21 11 1 FCC Label 21 12 Packaging Specifications 22 12 1 Collective Packaging Specification 23 13 Durability 24 13 1 Electrical Noise 24 13 2 Static Electricity 24 13 3 Shock 24 13 3 1 Drop Test without packaging 24 13 3 2 Drop Test with individual ...

Page 5: ...ther 28 16 5 AC DC Adapter 28 17 Mechanical Drawing 29 Table of Figures Figure 1 Depth of field 13 Figure 2 Pitch skew and tilt 14 Figure 3 Curvature 15 Figure 4 Aiming patterns 16 Figure 5 Serial number diagram 21 Figure 6 FCC label 21 Figure 7 Individual packaging 22 Figure 8 Collective packaging 23 Figure 9 Mechanical drawing 29 ...

Page 6: ... decoder that processes data faster and provides smoother scanning of both linear 1D and 2D symbologies Wireless communication compliant with IEEE 802 15 4 an interface standard for ZigBee physical layer and MAC layer is the interface between the OPI 4002 and a host system The scanner is supplied with an IEEE 802 15 4 dongle to establish wireless communication through the USB port of hosting hardw...

Page 7: ...8 EAN 128 MicroPDF417 GS1 Databar RSS Micro QR Code IATA PDF417 Industrial 2of5 QR Code Interleaved 2of5 ISBN ISSN ISMN Matrix2of5 MSI Plessey S Code Telepen Tri Optic UK Plessey 3 Physical Features 3 1 Dimensions W 58 1 mm x D 42 4 mm x H 163 9 mm 3 2 Weight 125 grams max 3 3 Color Light gray 4 Environmental Specifications 4 1 Operating Temperature and Humidity Temperature 0 to 40 C Humidity 5 to...

Page 8: ...ary battery Nominal capacity 1100 mAh Nominal voltage 3 6 V Item Specifications Conditions 15 mA max When idle 250 mA max When scanning Consumption current 550 mA typ When charging 5 2 Battery Operating Time and Charging Time Items Specifications Conditions Battery life 30 hours min 1 scan 5 s Discharge and charge 300 times Battery capacity 70 1C charging Charging time 3 hours Time necessary to fu...

Page 9: ...Operating Indicators 5 4 1 LED Indicator and Buzzer The OPI 4002 uses LEDs and a buzzer to indicate its status State Color Display Operating State Buzzer Red Lighting Shows that the scanner is being charged Charging Green Lighting The light changes from red to green when charging is completed Green Blinking Shows that the scan or transmission was executed normally Trrr Red Blinking Shows that the ...

Page 10: ...ations to read about scanning performance 7 Technical Specifications The conditions for technical specifications are as follows unless otherwise specified in each section Conditions Ambient temperature and humidity Room temperature 5 to 35º C Room humidity 45 to 85 RH Ambient light 1000 to 1500 lx on the surface of a barcode Light source 3 wavelength inverter fluorescent light Angles α 0 β 15 γ 0 ...

Page 11: ...ICS test samples Other charts are printed by a regular printer N W Ratio 1 2 5 Angle α 0 β 15 γ 0 Curvature R 7 2 Test Samples 2D Symbologies PDF417 Resolution Error Correction PCS Size mm Characters 0 127 mm Level 4 0 9 13 x 8 17 0 254 mm Level 4 0 9 26 x 16 5 17 0 339 mm Level 4 0 9 35 x 22 17 Charts are printed by a regular printer Horizontal to vertical ratio is 3 1 Data Matrix Resolution Mode...

Page 12: ...pace and quiet zone PCS Reflectance of white bar Reflectance of black bar Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window Keep the optical window clean 7 4 Minimum Resolution Resolution Symbology 0 1 mm Code 39 0 127 mm PDF417 0 169 mm QRCode 0 169 mm Data Matrix ...

Page 13: ...Field The depth of field is measured from the edge of the optical window Figure 1 Depth of field Symbology Resolution mm Decode Depth mm PCS Code 39 0 1 0 254 55 75 30 105 0 9 PDF417 0 127 0 339 45 80 25 130 0 9 QR Code 0 169 0 339 45 75 25 100 0 9 Data Matrix 0 169 0 339 45 70 35 95 0 9 ...

Page 14: ...e formula being β 15 Notes When a barcode is printed on glossy paper or a card case it may cause difficulties in scanning due to the reflection of lighting LEDs To improve scanning performance under these circumstances scan the barcode with a scan angle of 15 degrees or with lighting LEDs turned off When scanning a barcode with lighting LEDs turned off confirm that there is enough ambient lighting...

Page 15: ...oding performance is guaranteed when R 15 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm Figure 3 Curvature Conditions Barcode Sample Symbology 13 digit JAN resolution 0 26 mm PCS 0 9 mm Distance 56 mm from the front edge of the scanner Angle α 0 β 15 γ 0 ...

Page 16: ...ral LED light patterns green and square shaped overlap where two dots meet To scan a barcode within the aiming range make sure that two central LED light patterns overlap then place the center of the overlapping LED light patterns on the center of the barcode To scan a barcode wider than a width of the aiming range aim at the barcode from further away Make sure that the barcode is between two LED ...

Page 17: ...may be disconnected by other devices using the same absorption rate Baud rate and communication distance are affected by obstacles wave conditions or a device at the other end This product is equipped with an antenna Bringing this product too close to a metallic object may affect communication Anticipated interference distance is 10 m or less 9 2 2 Frequency Band This product uses the 2 4 GHz freq...

Page 18: ...nfiguring Settings by Reading Menu Barcode Labels Communication parameter settings for the OPI 4002 can be configured by scanning menu labels Refer to the instruction manual for further information about menu labels 10 2 1 Address Registration to Connect with OPA 1001 Read an address barcode printed on the label attached to the OPA 1001 cradle Confirm that the OPA 1001 is connected to the OPI 4002...

Page 19: ...ate CD Set Prefix Set Suffix Other UPC A X CR UPC A Add on X X CR UPC E X CR UPC E Add on X X CR EAN 13 X CR EAN 13 Add on X X CR EAN 8 X CR EAN 8 Add on X X CR Aztec Code X X CR Aztec Runes X X X CR Codabar NW 7 X X CR Not transmit ST SP Code 39 X X CR Not transmit ST SP Code 93 X CR Code 128 X CR Data Matrix ECC0 140 X X X CR Data Matrix ECC200 X X CR GS1 128 EAN UCC 128 X X X CR GS1 DataBar RSS...

Page 20: ...ngth In the Transmit CD column means Transmit check digit and X means Do not transmit check digit In the Calculate CD column means Calculate check digit and X means Do not calculate check digit means not supported In the Prefix column means there is no prefix setting 10 4 Default Settings 2 Read Options Trigger Buzzer Item Default Setting Setting the number of characters Fixed length OFF all codes...

Page 21: ...ion Settings Item Setting Set IEEE address None Wireless channel CH15 Encryption Enabled Data memorizing Disabled 11 Serial Number and Labeling The serial number is written on the following label attached to the scanner Figure 5 Serial number diagram 11 1 FCC Label Figure 6 FCC label ...

Page 22: ... w i ndow dow n w hen you put t he scanner i n t he box U ser s m anual 5J0070 U S B D O N G LE X F1O P A 1001 A pr oduc t f i ni s hed wi t h packi ng U S B D O N G LE M A D E I N JA P A N M odel N o O P I 4002 S pec N o UF1O PI 4002 S er i al N o Q uant i t y 1 R o BAR CODE LABEL for BOX 3A0002 D i spl ay f or t he ser i al N o Fr om 000001 t o 999999 S am e num ber as t he scanner N um ber of s...

Page 23: ...I N JA P A N P r oduct O P I 4002 PO S pec JP N U F 1O P I 4002 Q t y S N f r om 000001 S N t o 000 M i ssi ng S er i al N um ber M i ssi ng Q t y 1 2 R O M Ver S hi ppi ng D at e 2006 O PTO ELEC TR O N I C S C o Lt d R o S pec E U R S pec U S A C N o M A D E I N JA P A N 3 O PTO ELEC TR O N I C S C o Lt d M i ssi ng S e r i a l N um be r M i ssi n g Q t y 4 5 6 7 8 9 1 0 1 1 1 2 U N I V E R S A L...

Page 24: ...d after the following drop test Drop Test Drop the scanner from 1 5 meters onto a concrete floor three times on each of its six sides Scratches on the chassis are not counted as a defect 13 3 2 Drop Test with individual packaging No malfunction occurred after the following drop test Drop Test Dropped the individually packaged scanner from 1 5 meters onto a concrete floor once on its one corner thr...

Page 25: ...ter shall have no harmful effect when the enclosure is tilted at an angle up to 15 from its normal position 14 Reliability MTBF Mean Time Between Failures of this product is 50 000 hours The estimate of MTBF and product life cycle is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock The MTTR Mean Time To Repair of...

Page 26: ...used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interferenc...

Page 27: ...ies are prohibited under the Radio Law Remodeling and disassembly Peeling off the certificate label 15 7 State of California Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate To comply with California Perchlorate Best Practice Regulations and the Law for the Promotion of Utilization of Recyclable Resources Japan products that may contain Perchlora...

Page 28: ...y Do not immerse the scanner in liquids Do not use in dusty environments Do not subject the scanner to chemicals Do not insert foreign substances into the device 16 4 Other Do not plug unplug the connectors before disconnecting the power Do not attempt to disassemble modify or update this device Do not use near microwaves medical devices or RF emitting devices The scanner may not perform properly ...

Page 29: ...Opticon OPI 4002 Specifications Manual 29 17 Mechanical Drawing Figure 9 Mechanical drawing ...