background image

 

 

 

IS4225 ScanGlove

®

 

Laser Bar Code Scanner 

Installation and User’s Guide 

Summary of Contents for IS4225 ScanGlove

Page 1: ...IS4225 ScanGlove Laser Bar Code Scanner Installation and User s Guide ...

Page 2: ...ing from the furnishing performance or use of this manual This document contains propriety information that is protected by copyright All rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 1999 2010 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks Metrologic ...

Page 3: ...arts of the Scanner 4 Visual Indicators 5 Audible Indicators 6 Labels 7 Maintenance 8 Depth of Field 9 Object Detection Device 10 Specifications 12 Default Settings 13 Troubleshooting Guide 19 Regulatory Compliance 20 Patents 23 Limited Warranty 24 Index 25 Customer Support 27 Technical Assistance 27 Product Service and Repair 28 ...

Page 4: ......

Page 5: ...that use a RS232 Keyboard Wedge Stand Alone Keyboard Light Pen Emulation or USB interfaces All models have Flash upgradeable firmware For additional information on other system interfaces please call a Customer Service Representative SCANGLOVE MODEL NO INTERFACE IS4225 38 USB Keyboard IS4225 41D RS232 with Breakaway Cable and DIN Connector IS4225 47 PC Keyboard Wedge and Stand Alone Keyboard IS422...

Page 6: ...e red LED will flash the green LED will flash and then the scanner will beep once 2 See power source caution statement on page 7 of this manual To maintain compliance with federal regulations 21 CFR Part 1040 10 section f 6 the scanner must be plugged into an electrical outlet with a switch accessible to the user or be powered by a host system containing a switch that will disable power to the sca...

Page 7: ... 2 Scan the bar code s for the desired parameter s The scanner will beep once 3 Scan the EXIT CONFIGURATION MODE bar code to exit and save the new parameter settings The scanner will beep three times If during the configuration process there is a need to return the scanner to the original factory settings scan the recall defaults bar code in the MetroSelect Configuration Guide All settings selecte...

Page 8: ... the laser is on Red Output Window Laser Aperture Object Detection Device If a specified time has elapsed without any scanning the unit will enter a standby mode To reactivate the unit place an object in front of the object detection field The red LED will turn on when the scanner is ready to scan Communication Power Cable This cable s termination is application dependent 4 ...

Page 9: ...ect is detected in the scan field If the scanner cannot detect a bar code within approximately 2 5 seconds the unit will go into standby mode then the red LED will shut off indicating that the laser is no longer on Steady Red LED Green Flash When the scanner successfully reads a bar code the green LED will flash and the unit will beep once If the green LED does not flash or the scanner does not be...

Page 10: ...de read is not successful Razzberry Tone If upon power up the scanner emits a razzberry tone the scanner has failed diagnostics The scanner can be configured to emit a razzberry tone when the timeout occurs during communication between the host and scanner Refer to Scanner Operation Communication Timeout Options in the MetroSelect Single Line Guide Three Beeps When entering configuration mode the ...

Page 11: ... laser light emitted from this aperture The following Figure shows examples of these labels Figure 2 Caution and Serial Number Labels Labels not shown to scale Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 1 7 To maintain compliance with standard CSA C22 2 No 6095...

Page 12: ...ow can interfere with the unit s performance If the window requires cleaning use only a mild glass cleaner containing no ammonia When cleaning the window spray the cleaner onto a lint free non abrasive cleaning cloth then gently wipe the window clean ...

Page 13: ...DEPTH OF FIELD Minimum Bar Code Element Width Standard A B C D E m m 17 19 25 33 53 mil 6 8 7 5 10 4 13 21 Figure 3 Depth of Field Specifications are subject to change without notice 9 ...

Page 14: ...ice initiates the scan process if it senses an object anywhere from the face of the window out to approximately 9 to 13 If the object is removed from the field during the scanning process the laser turns off and the scanner re enters standby mode However if the object stays in the field the laser remains on for up to 2 5 seconds trying to detect another bar code If the scanner does not detect a ba...

Page 15: ...he scanner To mitigate the problem please try one of the following suggestions 1 Avoid mounting the scanner directly facing the ambient light source 2 Avoid mounting the scanner facing a light colored or reflective surface 3 Avoid mounting the scanner towards a surface at a distance close to the long range 9 11 of object detection 4 Configure the object detection range to short 4 7 11 ...

Page 16: ...nd density Roll Pitch Skew 30 56 58 100 mm distance Sweep Angle 60 Beeper Operation 3 tones or no beep Indicators LED red laser on ready to scan green good read decoding MECHANICAL Length x Width x Height 70 mm x 49 mm x 24 mm 2 75 x 1 94 x 0 94 Weight 105 grams 3 7 oz Cable Termination Application Dependent ELECTRICAL Input Voltage 5VDC 0 25V Power 0 75 W Operating Current 135 mA DC Transformers ...

Page 17: ... in the charts on the following pages a check mark will appear Parameter Default RS232 Light Pen Keyboard Wedge USB Enter Configuration Mode After Any Scan Enter Configuration Mode Only on First Scan Short Range Activation Long Range Activation Normal Scan Custom Scan DTR Activation DC2 Activation Address Based Activation NOREAD message Transmission Turn on Green LED during NOREAD Transmit Same Sy...

Page 18: ...S CTS Character RTS CTS Message RTS CTS ACK NAK XON XOFF No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 10 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay 100 Millisecond Intercharacter Delay DTR Input DTR Scan Disable DE Disable Command LRC Calc Transmit RS232 Start LRC on first RS232 Byte Start LRC on Second RS232 Byte Carriage ...

Page 19: ...C EAN Full ASCII code 39 Code 39 Codabar Code 128 Code 93 Code 11 GS1 DataBar Enable GS1 DataBar ID e0 GS1 DataBar App ID 01 GS1 DataBar Check Digit GS1 DataBar Expanded Enable Expanded ID e0 GS1 DataBar Limited Enable GS1 DataBar Limited ID e0 GS1 DataBar Limited App ID 01 GS1 DataBar Limited Check Digit Interleaved 2 of 5 Hong Kong Matrix 2 of 5 Airline 2 of 5 Minimum 1 Character Code Length Min...

Page 20: ...nvert EAN 8 to EAN 13 Prefix ID for UPC EAN 2 Digit Supplements Scan 5 Digit Supplements Scan Bookland Scan Supplement Required Bookland to ISNB Transmit ISBN CD Mod 43 Check digit Code 39 Transmit Mod 43 Check Digit Code 39 Transmit Start Stop Code 39 CLSI Editing Enable ITF Check Digit Transmit Mod 10 ITF Check Digit 2 of 5 Symbol Lengths Variable ISBN Reformatting Coupon Code 128 C1 Transmit Co...

Page 21: ... Digit UK Plessy UK Plessey Check Digit UK Plessey Special Format A to X conversion UK Scan Count Test Mode Scanability Test Mode Normal Scan Operating Test Mode Default to ScanPal Communication parameters Code ID Code ID Sanyo 635 ECR Protocol Post Software ID characters Newcode Mode A Newcode Mode B SNI Beetle Mode BIO DATA Mode Enable Sineko Mode Enable Caps Lock Mode for MI951 external wedge R...

Page 22: ...ble Prefixes and Suffixes SNI Beetle Mode AT Keyboard Type XT Keyboard Type PS2 Keyboard USA Keyboard Belgium Keyboard France Keyboard Germany Keyboard Spain Keyboard Italy Keyboard UK Keyboard IBM KDB4700 Financial Keyboard Alt Mode Auto Detection or Caps Lock User Defined Caps Lock F0H Break Code Transmission 800 Microsecond Delay Enter Scan Code 15 Millisecond Delay Enter Scan Code 7 5 Millisec...

Page 23: ...host Check the host system s power cable the outlet and power strip No LEDs beep and there is no visible laser No power is being supplied from the USB port The IS4225 requests 100mA from the USB port If the USB port cannot supply this a notification window will appear on the screen After scanning a bar code the Red and Green LEDs are on but no data is being transmitted to the host The scanner is n...

Page 24: ...ns Le client ne doit en aucun cas essayer d entretenir lui même le scanner ou le laser Ne regardez jamais directement le rayon laser même si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous exposez à une rayonnement laser qú êst hazardous L emploi d appareils optiques avec cet équipement laser augmente le risque d endommagement de...

Page 25: ...terference at their own expense Any unauthorized changes or modifications to this equipment could void the user s authority to operate this device This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesi...

Page 26: ...he FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular ...

Page 27: ...23 PATENTS For patent information please refer to www honeywellaidc com patents ...

Page 28: ... EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT HII S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR R...

Page 29: ... 12 F function 13 G good read 12 green LED 4 5 6 H host 4 10 13 18 humidity 12 I immunity 21 indicators 5 6 12 input voltage 12 installation 1 interfaces 1 K keyboard wedge 1 12 13 18 L labels 7 laser 20 LED 4 5 6 10 12 19 light levels 12 light pen emulation 1 12 13 18 light source 12 long range activation 1 10 13 M maintenance 8 mechanical 12 min bar width 12 model number 7 N notices 22 O operati...

Page 30: ... pattern 12 scan speed 1 12 serial number 7 shock 12 short range activation 1 10 13 software 19 specifications 4 12 stand 1 12 storage 12 system interfaces 1 12 T temperature 12 termination 12 test 16 test code 19 tones 6 12 troubleshooting 19 U USB 13 18 V ventilation 12 visual 5 6 W warranty 24 Watts 12 weight 12 window 4 5 6 8 10 ...

Page 31: ...m Mexico Telephone 803 835 8000 E mail hsmlasupport honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail hsmeurosupport honeywell com Hong Kong Telephone 852 29536436 Fax 851 2511 3557 E mail aptechsupport honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail aptechsupport honeywell com China Telephone 86 800 828 2803 Fax 86 512 6762 2...

Page 32: ... 21 3535 9100 Fax 55 21 3535 9105 E mail brservice honeywell com Mexico Telephone 52 55 5203 2100 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euroservice honeywell com Hong Kong Telephone 852 29536436 Fax 851 2511 3557 E mail apservice honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail a...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 00 02258 Rev E May 2010 ...

Reviews: