≈ 650 μs
< 300 μs
< 300 μs
OSSD2
OSSD1
Figure 79: Shut-down test
< 300 μs
OSSD2
OSSD1
Figure 80: Voltage test
12.5
EFI status information and control commands
Overview
If devices are connected together via EFI, EFI status information and control commands
are exchanged. The following two tables show the status information that can be
retrieved and the possible control commands for the device.
NOTE
•
The information in square brackets reflects the names used in the CDS and in the
Flexi Soft Designer.
•
If the devices are operated in the compatibility mode, then restricted EFI status
information and control commands are available.
Status information
Table 38: Status information (data from the safety laser scanner)
Status information
Meaning/effect
•
Logical 1, if the internal OSSD of the device is in
the ON state (green)
•
Logical 0, if the OSSD of the device is in the OFF
state (red)
12
TECHNICAL DATA
132
O P E R A T I N G I N S T R U C T I O N S | S300
8010948/ZA21/2020-06-18 | SICK
Subject to change without notice