22
Some projectors may have a low-voltage trigger that will allow your screen to drop when it is turned on.
Installer must supply conductor wire in the length and guage needed..
Use the supplied cable for all set-up procedures. It is recommended to permanently install the wall switch in
an accessible location for future limit setting and troubleshooting procedures. Plug in the RJ45 end into the
control center, and plug the smaller RJ9 end into the wall switch.
Tip DC +3V to +12V
50mA min
Sleeve
18 Gauge or Larger
Shielded 2 Conductor wiring
65ft (20 m) Max
9 ft (2.75m) Provided
If Longer cable is needed it must be shielded
RJ45
RJ9
Wall Switch
POWER & CONTROL
Low Voltage Trigger (Optional)
POWER & CONTROL
Wall Switch