Si Tech Glove Lock QCP Скачать руководство пользователя страница 4

www.sitech.se

3.1

 Put your hand through the seal and fit the 

Equalization Tube between seal and wrist. 
Make sure the Equalization Tube reaches 
all the way through the seal.

4.1

 Turn the Lock and Release ring in opposite direction compared to the donning procedure. 

Turn until the Glove Ring and the Assembly Ring are separated. 

Tip!

 Keep glove on when 

doffing second ring. The glove provide a higher friction against the rubber ring.

Equalization Tube

3.2

 Join the rings together (make sure that 

the O-ring and sealing surface [5.3] are 
properly cleaned and lubricated).

3.3

 When the Glove Ring and the Suit

Ring has been joined together just turn the 
Lock and Release Ring as the image displays. 
Turn the Lock and Release Ring until it stops. 
When this procedure has been made properly 
you should only be able to see part of the 
edge of the bayonet (as displayed in the 
right section of the image box). 

Bayonet

2.1

 Start by finding appropriate Spanner    

Ring. When pressing the Spanner Ring and
glove into the Glove Ring they shall slide    
without use of excessive force. 

2.4

 Press the glove with Spanner Ring 

evenly into the Glove Ring.

2.5

 Check for creases on the glove as 

creases may cause leakage.

2.6

 Test the strength of attachment by 

pulling Glove Ring and Glove in the 
opposite direction. If the assembly does 
not hold together, please change the 
Spanner Ring to a thicker one.

2.2

 Place the Spanner Ring on the inside of 

the glove, make sure to find proper position   
for optimized length of the glove.

2.3

 Fold the glove shaft inwards over the  

Spanner Ring (latex gloves can be fitted    
and folded the opposite way).

After you have conducted a testdive you may trim the excess material on the glove shaft 
for optimized function, comfort and visual appearance.

Whatever method chosen, be certain the wrist seal, be it latex or silicone, is properly treated. 
Always make a leakage and stress test on your drysuit seals before diving.

Содержание Glove Lock QCP

Страница 1: ...www sitech se Glove Lock QCP User Manual Photo Anders Salesjö Lysekil ...

Страница 2: ...w and black Spanner Rings Components Quick Cuff is a Modular Quick Change Solution designed to simplify change of broken or torn wrist seals on drysuits We want to congratulate you on your purchase of the Glove Lock QCP a Dry Glove system developed and manufactured by SI TECH in Sweden By reading this manual you are only some simple steps away from diving it The Glove Lock QCP is an easy to mount ...

Страница 3: ...before the Glove Lock QCP The Glove Lock QCP however was designed so that the user of Quick Cuff could benefit from it when choosing the Glove Lock QCP 1b 1 Located on the inside of the Suit Ring of the Glove Lock QCP there is an edge that will act as fixation point for the soft Wrist Ring of the Quick Cuff System 1b 2 Squeeze the soft Wrist Ring and insert it into the Suit Ring of the Glove Lock ...

Страница 4: ...n the right section of the image box Bayonet 2 1 Start by finding appropriate Spanner Ring When pressing the Spanner Ring and glove into the Glove Ring they shall slide without use of excessive force 2 4 Press the glove with Spanner Ring evenly into the Glove Ring 2 5 Check for creases on the glove as creases may cause leakage 2 6 Test the strength of attachment by pulling Glove Ring and Glove in ...

Страница 5: ...ECH Lube Stick Troubleshooting If high resistance occurs disassemble and lubricate with SI TECH Lube Stick If the rings are misaligned disassemble and don again Sand and debris caught up by lubricant on Glove Ring and or Suit Ring may cause leakage if not removed Remove O ring and make sure the O ring groove and adjoining surface on Suit Ring is clean before replacing the O ring To change or to cl...

Страница 6: ...al compoents for military purposes Inhouse capabilities Development and production is made in house at our facilities in Brastad Sweden Inhouse competencies include CAD constr uction Injection Molding CNC Machining EMD Machining Assembly Sales and Marketing Logistics and Administration Our team of engineers sales and marketing personell have close co operation with the distributors and end users o...

Страница 7: ...www sitech se SI TECH AB Glove Lock QCP manual Version 2 0 February 6 2013 ...