www.sitech.se
3.1
Put your hand through the seal and fit the
Equalization Tube between seal and wrist.
Make sure the Equalization Tube reaches
all the way through the seal.
4.1
Turn the Lock and Release ring in opposite direction compared to the donning procedure.
Turn until the Glove Ring and the Assembly Ring are separated.
Tip!
Keep glove on when
doffing second ring. The glove provide a higher friction against the rubber ring.
Equalization Tube
3.2
Join the rings together (make sure that
the O-ring and sealing surface [5.3] are
properly cleaned and lubricated).
3.3
When the Glove Ring and the Suit
Ring has been joined together just turn the
Lock and Release Ring as the image displays.
Turn the Lock and Release Ring until it stops.
When this procedure has been made properly
you should only be able to see part of the
edge of the bayonet (as displayed in the
right section of the image box).
Bayonet
2.1
Start by finding appropriate Spanner
Ring. When pressing the Spanner Ring and
glove into the Glove Ring they shall slide
without use of excessive force.
2.4
Press the glove with Spanner Ring
evenly into the Glove Ring.
2.5
Check for creases on the glove as
creases may cause leakage.
2.6
Test the strength of attachment by
pulling Glove Ring and Glove in the
opposite direction. If the assembly does
not hold together, please change the
Spanner Ring to a thicker one.
2.2
Place the Spanner Ring on the inside of
the glove, make sure to find proper position
for optimized length of the glove.
2.3
Fold the glove shaft inwards over the
Spanner Ring (latex gloves can be fitted
and folded the opposite way).
After you have conducted a testdive you may trim the excess material on the glove shaft
for optimized function, comfort and visual appearance.
Whatever method chosen, be certain the wrist seal, be it latex or silicone, is properly treated.
Always make a leakage and stress test on your drysuit seals before diving.