Troubleshooting (cont.)
Brewing Problems
Problem
Possible Causes
Service Check
Remedy
Brew cycle will
not start
• Controller faulty.
• Check to see that the
power is supplied to the
controller by following
instructions given in
the
Troubleshooting
section
on
Filling
Problems.
Once
touchpad and momentary
switch integrity is
assured (see above),
initiate a brew cycle
and check for 24 Vac
across brew valve.
• If there is not 24 Vac across
brew valve, replace control
board.
Sprayhead will not
stop dripping water
• Brew valve not closing
completely.
• Water in tank boiling.
• Visually inspect brew
valve at hose
connections.
• Remove sprayhead
and determine if drip is
coming from overflow.
• Clean lime from valve. Seat,
cup or entire valve may need
replacement.
• Reduce tank temperature.
If you still need help, call our Service Department at (800) 695-4500 (USA and Canada only) or (502) 425-4776
(Monday-Friday 8:00 a.m.-8:00 p.m. EST) or an authorized service center in your area. Please have the model
and serial number ready so that accurate information can be given.
Prior authorization must be obtained from Grindmaster Corporation’s Technical Services Department for all
warranty claims.
Содержание PB-330
Страница 2: ......
Страница 32: ...Page 32 Shuttle Brewers Airpot Shuttle Brewers Wiring Diagram Heater Configuration 3 Heater ...
Страница 33: ...Shuttle Brewers Airpot Shuttle Brewers Page 33 Wiring Diagram Heater Configuration 1 Heater ...
Страница 34: ...Page 34 Shuttle Brewers Airpot Shuttle Brewers ...
Страница 35: ...Shuttle Brewers Airpot Shuttle Brewers Page 35 ...