RO BOOSTER PUMP SYSTEM

Installation and Operation Instructions 

The SHURflo Reverse Osmosis (RO) Booster Pump System enables most RO filtration units to be used anywhere 

there  is  electrical  power  and  water.  The  system  was  developed  for  areas  where  the  average  incoming  water 

pressure may be below 40 psi., or even from a non-pressurized source (tank).  The booster pump maintains a high 

RO  feed  water  pressure,  ensuring  a  consistent  production  of  high  quality  RO  water.  The  system  includes  an 

accumulator tank pressure switch, which turns off the booster pump once the tank is full.  The compact design of 

the  system  and  minimal  connections  allow  it  to  be  easily  installed  under  a  sink.    Quiet  and  safe,  SHURflo  RO 

Booster Pump Systems will provide years of service.  

85 Series "High Flow" pumps are for RO filtration units that produce between 35–100 GPD

 [132–284 LPD]

CAUTION: 85  Series  RO  Booster  Pump  Systems

  MUST

  be  used  in  conjunction  with  RO  filtration  units  rated  to

produce at least 35 GPD  Failure to do so may result in excessive pressure 

(125 psi. [8.5 bar])

, resulting in 

damage to RO membrane, filter housings, and possible premature wear to the booster pump. 

70 / 80 Series "Low-Flow" pumps are for RO filtration units that produce up to 35 GPD  The 70-121 does not

require regulated inlet water, internal bypass is not affected by inlet pressure.

INSTALLATION GUIDELINES

1. The enclosure/pump should be placed as close to the RO unit as possible.  Located in an area that is dry, with

ambient temperatures between 40°–90°F 

[5°–35°C]

.   

2. 70 Series pumps may be mounted in any position.  If mounting vertically the pump head should be in the down

position so in the event of a leak, water will not enter the motor.  Secure the rubber feet with

#

8 hardware (not

provided).  DO NOT compress the feet.  Compressing the feet reduce their ability to isolate vibration/noise.

3. 80  &  85  Series  have  a  "keyhole"  slot  on  the  back  of  the  enclosure  for  vertical  mounting.  A  vertical  position

ensures air can purge from the booster pump.  If necessary, the booster pump may be positioned horizontally.

4. Turn OFF the incoming water supply line and relieve pressure at the water faucet.
NOTE:  RO filtration units may be configured with an outlet connection at the Pre-Filter.  RO units of this type permit

the  booster  pump  to  be  plumbed  between  the  "Pre"  and  "Post"  filters.  Refer  to  the  alternate  plumbing 

routings shown in the illustration. 

4. Connect  the  cold  water  Inlet  (

1

/

4

"  or

3

/

8

" O.D. flexible polyethylene) to the "

INLET

" port of the enclosure/pump.

Tubing  ends  should  have  clean,  square  cuts  to  prevent  leaks.  Install  the  tubing  into  the  John  Guest

®

  Quick

Connect fittings by pushing the tube in firmly until it stops.

5. Connect a suitable length of tubing from the "

OUTLET

" of the enclosure/pump to the RO unit.

6. Install the tank pressure switch into the accumulator tubing.  Insure proper connection of transformer and tank switch
7. Turn ON incoming water supply.
8. Plug the transformer into a 

GROUNDED 

outlet. The pump will operate until the accumulator tank is pressurized.  The

pump will then operate whenever the accumulator pressure drops below the pressure switch "turn on" setting.