And as so, the specification, which applies to each
of the chain outputs on the CU 6010 Central Units
does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004
Repeaters, bear in mind, that as the RP 6004
Repeater is repeating only one of the four outputs
A (A1 or A2) or B (B1 or B2) the max. number of
languages configured on the four outputs (1, 2,
3 and 4) is totally max. 16.
If more languages are required, Interpreter sets
for those languages have to be connected either
to another RP 6004 Repeater, which is connected
to the other of the two chains (A or B) on the CU
6010, or directly to the other of the two chains
(A or B) on a CU 6010.
‘Repeated chain’ connector
When connecting the RP 6004 Repeaters to the CU
6010 the first RP 6004 is connected to the ‘Loop
through’ connector. The next RP 6004 Repeaters
can be connected to either the other ‘Loop
through’ connector or to one of the ‘Repeated out’
connectors. If using the ‘Repeated’ outputs
maximum two more RP 6004 Repeaters can be
connected extending the maximum cable length
in one chain up to 650 m. The above schematic
is showing the connection using the ‘‘Repeated
out’ connectors.