RP 6004 Repeater 

General description 

The  RP  6004  Repeater  provides  repeater  and 
splitter functionality for the DCS 6000 system.  

One  CU  6010  Central  Unit  is  needed  in  each  DCS 
6000 system, however for expansion of the system 
the RP 6004 Repeater is suitable.  

The RP 6004 consist of the following main parts: 

 

Repeater  board  with  4  individual  repeated 
outputs. 

 

 

Features 

The main features of the RP 6004 Repeater are: 

 

4  outputs  for  connection  to  Delegate  Units, 
Interpreter Units etc.  

 

Loop  through  connectors  for  connecting 
additional RP 6004 or other units, which are 
part of the DCS 6000 system. 

 

Delayed  switching  on  of  power  to  the  four 
chains,  to  minimise  the  total  ‘switch-on’ 
current on the Mains supply. 

 

Designed  in  compact  cabinet  for  easy 
installing remotely. 

 

Optional 19” brackets. 

User Controls, indications & connectors 

Front plate layout  

Front plate controls 

The RP 6004 Repeater does not feature any controls 
or  displays,  however  the  following  indications  and 
connectors are available: 

Loop through connectors 

RJ45 connector, 2 pieces 

DCS-LAN connectors. Used for connection to one of 
the  chain  connector  on  the  CU  6010  for  repeating 
the DCS-LAN chain.  

The  second  connector  is  for  connection  to  other 
units  with  DCS-LAN  connector,  such  as  more  RP 
6004.  

The loop through connectors has auto-termination. 

Repeated Chain 1, 2, 3 & 4 

RJ45 connector, 4 pieces 

DCS-LAN  connectors.  Used  for  connection  to 
DM/CM6xxx,  CS6032,  EX6010,  AO6008,  JB 
6002/4 or IS6032 Interpreter Sets.  

Unused repeated chains do not need termination  

Power LED 

 

Those  LED  light  up  when  Power  is  available  on 
the connector next to the LED 

Incoming data LED 

Those LED flashes, when the unit receives 
incoming data from connected units on the 
connector next to the LED.

System design 

There are  no settings to be done on the RP 6004 
Repeater.  

However it is important to observe, that the unit 
is  only  repeating  one  of  the  chains  on  the  CU 
6010 Central Unit.  

Содержание RP 6004

Страница 1: ...2015 Shure Incorporated User Manual RP 6004 rev F docx Conferencing and Discussion Systems RP 6004 Repeater USER GUIDE...

Страница 2: ...ts 6 Central equipment etc 6 Interpreter equipment 6 Conference units and Ch selectors 6 Accessories 6 Operating instructions 7 RP 6004 Repeater 7 General description 7 Features 7 User Controls indica...

Страница 3: ...and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi...

Страница 4: ...ever have to ship the unit For maximum protection re pack the unit as originally packed from the factory Warranty The individual units in the DCS 6000 system are minimum covered by 24 months warranty...

Страница 5: ...clude Channel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Cent...

Страница 6: ...portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F Conference Uni...

Страница 7: ...Front plate layout Front plate controls The RP 6004 Repeater does not feature any controls or displays however the following indications and connectors are available Loop through connectors RJ45 conn...

Страница 8: ...ets for those languages have to be connected either to another RP 6004 Repeater which is connected to the other of the two chains A or B on the CU 6010 or directly to the other of the two chains A or...

Страница 9: ...of RP 6004 can be connected by using the Loop through connector The practical limitation is the maximum cable length in one chain which is 200 m and supply of power to the RP 6004 repeaters The follow...

Страница 10: ...3 and 4 is totally max 16 If more languages are required Interpreter sets for those languages have to be divided between both chains A or B on the CU 6010 Normally the languages are supposed to be div...

Страница 11: ...DCS 6000 Digital Conference System User Manual 11 Typical schematics The following schematics are showing various configurations Large sized conference microphone system...

Страница 12: ...DCS 6000 Digital Conference System User Manual 12 Various configurations with RP 6004 Repeater and PS 6000 Power Supply...

Страница 13: ...ded RJ45 connectors and not U UTP cable which are unshielded How to wire a Cat5e EIA 568 B cable to a RJ45 con Pin Function Connector 1 Connector 2 1 In going ORG WHT ORG WHT 2 In going ORG ORG 3 48V...

Страница 14: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Отзывы: