Shure RP 6004 Скачать руководство пользователя страница 3

DIS Digital Conference System 

User Manual

 

 

3

 

Important 

Installation precautions 

Do  not  install  the  unit  in  a  location  near  heat 
sources such as radiators or air ducts, or in a place 
exposed  to  direct  sunlight,  excessive  dust  or 
humidity, mechanical vibration or shock. 

To avoid moisture condensations do not install the 
unit where the temperature may rise rapidly. 

Compliance 

The equipment is intended to be used in 
professional audio applications. 

Note: This device is not intended to be connected 
directly to a public internet network. 

EMC conformance to Environment E2: 
Commercial and Light Industrial. 

Testing is based on the use of supplied and 
recommended cable types. 

The use of other than shielded (screened) cable 
types may degrade EMC performance. 

Changes or modifications not expressly approved 
by Shure Incorporated could void your authority 
to operate this equipment. 

This Class B digital apparatus complies with 
Canadian ICES-003. Cet appareil numérique de la 
classe B est conforme à la norme NMB-003 du 
Canada. 

Authorized under the verification provision of FCC 
Part 15B. 

Please follow your regional recycling scheme for 
batteries, packaging, and electronic waste. 

Information to the user 

This equipment has been tested and found to 
comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable 
protection against harmful interference in a 
residential installation.  

This equipment generates uses and can radiate 
radio frequency energy and, if not installed and 
used in accordance with the instructions, may 
cause harmful interference to radio 
communications. However, there is no guarantee 
that interference will not occur in a particular 
installation. If this equipment does cause harmful 
interference to radio or television reception, 
which can be determined by turning the 
equipment off and on, the user is encouraged to 
try to correct the interference by one or more of 
the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase  the  separation  between  the 
equipment and the receiver. 

 

Connect  the  equipment  to  an  outlet  on  a 
circuit different from that to which the  

 

receiver is connected. 

 

Consult  the  dealer  or  an  experienced 
radio/TV technician for help. 

 

Cleaning 

To  keep  the  cabinet  in  its  original  condition, 
periodically  clean  it  with  a  soft  cloth.  Stubborn 
stains  may  be  removed  with  a  cloth  lightly 

dampened with a mild detergent solution. Never 
use organic solvents such as thinners or abrasive 
cleaners since these will damage the cabinet. 

Repacking 

Save  the  original  shipping  cardboard  box  and 
packing  material;  they  will  become  handy  if  you 

Содержание RP 6004

Страница 1: ...2015 Shure Incorporated User Manual RP 6004 rev F docx Conferencing and Discussion Systems RP 6004 Repeater USER GUIDE...

Страница 2: ...ts 6 Central equipment etc 6 Interpreter equipment 6 Conference units and Ch selectors 6 Accessories 6 Operating instructions 7 RP 6004 Repeater 7 General description 7 Features 7 User Controls indica...

Страница 3: ...and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi...

Страница 4: ...ever have to ship the unit For maximum protection re pack the unit as originally packed from the factory Warranty The individual units in the DCS 6000 system are minimum covered by 24 months warranty...

Страница 5: ...clude Channel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Cent...

Страница 6: ...portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F Conference Uni...

Страница 7: ...Front plate layout Front plate controls The RP 6004 Repeater does not feature any controls or displays however the following indications and connectors are available Loop through connectors RJ45 conn...

Страница 8: ...ets for those languages have to be connected either to another RP 6004 Repeater which is connected to the other of the two chains A or B on the CU 6010 or directly to the other of the two chains A or...

Страница 9: ...of RP 6004 can be connected by using the Loop through connector The practical limitation is the maximum cable length in one chain which is 200 m and supply of power to the RP 6004 repeaters The follow...

Страница 10: ...3 and 4 is totally max 16 If more languages are required Interpreter sets for those languages have to be divided between both chains A or B on the CU 6010 Normally the languages are supposed to be div...

Страница 11: ...DCS 6000 Digital Conference System User Manual 11 Typical schematics The following schematics are showing various configurations Large sized conference microphone system...

Страница 12: ...DCS 6000 Digital Conference System User Manual 12 Various configurations with RP 6004 Repeater and PS 6000 Power Supply...

Страница 13: ...ded RJ45 connectors and not U UTP cable which are unshielded How to wire a Cat5e EIA 568 B cable to a RJ45 con Pin Function Connector 1 Connector 2 1 In going ORG WHT ORG WHT 2 In going ORG ORG 3 48V...

Страница 14: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Отзывы: