background image

Shure Incorporated

34/59

1.

2.

3.

Learn more and download at 

www.shure.com/designer

.

Accessing the Web Application

The Shure Web Server Discovery application finds all Shure devices on the network that feature a web-based GUI. Follow 

these steps to install the software and access the web application:

 Install the Shure Discovery application

Download and install the Shure Discovery application from www.shure.com. This automatically installs the required Bonjour 

device discovery tool on the computer.

 Connect the network

Ensure the computer and the hardware are on the same network.

 Launch the Discovery application

The app displays all Shure devices that feature a GUI.

 Identify the hardware

Double-click on a device to open its GUI in a web browser.

 Bookmark the device's web application (recommended)

Bookmark the device's DNS name to access the GUI without the Shure Discovery app.

Web Application Browser Compatibility

The web application is compatible with all HTML5-supported browsers. To ensure the best performance, disabling hardware 

acceleration and unused plug-ins is recommended.

Accessing the Web Application without the Discovery App

If the Discovery application is not installed, the web application can be accessed by typing the DNS name into an internet 

browser. The DNS name is derived from model of the unit, in combination with the last three bytes (six digits) of the MAC ad­

dress, and ending in .local.

Format Example: If the MAC address of a unit is 00:0E:DD:AA:BB:CC, then the link is written as follows:

MXA910

http://MXA910-aabbcc.local

How to Update Firmware Using Designer

Applies to Designer 4.2 and newer.

Before setting up devices, check for firmware updates using Designer to take advantage of new features and improvements. 

You can also install firmware using 

Shure Update Utility

 for most products.

To update:

Open Designer. If there's new firmware that you haven't downloaded yet, Designer shows a banner with the number of 

updates available. Click to download firmware.

Go to 

Online devices

 and find your devices.

Choose a firmware version for each device from the 

Available firmware

 column. Make sure that no one is editing device 

settings during an update.

Содержание Microflex Advance MXA910

Страница 1: ...0W A MXA910W US Ceiling Array Microphone Shure MXA910 ceiling array microphone user guide Includes mounting instructions specifications command strings best practices and mi crophone configuration det...

Страница 2: ...nc 19 Installation 20 Microphone Placement 20 Installing the Array Microphone 22 Model Variations 22 Rubber Scratch Protectors MXA910 and MXA910 60CM 2 3 Ceiling Installation MXA910 and MXA910 60CM 23...

Страница 3: ...47 QoS Quality of Service Settings 47 Switch and Cable Recommendations for Dante Network ing 48 Networking Best Practices 48 Device IP Configuration 48 Device IP Settings 48 Configuring IP Settings 4...

Страница 4: ...and lawful for use in other mounting configurations such as with hard ceilings or suspended from a VESA pole or suspension wiring anywhere in the world The MXA910W US is now available for 24 ceiling...

Страница 5: ...easiest way to route audio and apply DSP is with Designer s Optimize workflow Optimize automatically routes audio sig nals applies DSP settings turns on mute synchronization and enables LED logic cont...

Страница 6: ...huddle rooms and multi purpose spaces The ceiling array uses Shure s Steerable Coverage with Autofocus technology 8 highly directional pickup lobes capture participant audio from overhead continually...

Страница 7: ...ree update Software Control Shure Designer system configuration software provides comprehensive microphone and pattern control With Designer you can also design coverage with online and offline device...

Страница 8: ...e on a podium connects to the Dante audio network through a Shure Network Interface model ANI4IN for a completely networked conferencing system Far end audio network to loudspeakers Dante enabled loud...

Страница 9: ...ork Port RJ 45 jack for network connection Network Status LED Green Off no network link On network link established Flashing network link active Network Speed LED Amber Off 10 100 Mbps On 1 Gbps LED L...

Страница 10: ...e moves quickly back and forth across bar Note When the LED is disabled the LED still illuminates while the device is powering up and when an error state occurs Customizing Lighting Settings Custom LE...

Страница 11: ...at the Shure logo it is the second hole in the fourth row from the top Reset Modes Network reset press button for 4 8 seconds Resets all Shure control and audio network IP settings to factory defaults...

Страница 12: ...eleting unnecessary routes Checking levels and adjusting gain Verifying that AEC reference signals are correctly routed Fine tuning DSP blocks as needed Compatible devices MXA910 MXA710 MXA310 P300 In...

Страница 13: ...control over the physical coverage and audio channel settings with user presets to quickly switch between configurations Each lobe is moved according to seating arrangements with three width settings...

Страница 14: ...he channels by dragging or nudging them into place Distance values to the device and to the workspace 0 0 are calculated in the properties panel Use the grid to measure the precise placement As you mo...

Страница 15: ...echnology to fine tune each lobe s position in real time even if meeting participants lean back or stand up You ll see the lobes moving in Designer s coverage map as participants shift positions Autof...

Страница 16: ...these faders to adjust the gain of a talker after you are satisfied with the automixer s gating behavior Parametric Equalizer PEQ Maximize audio quality by adjusting the frequency response with the pa...

Страница 17: ...ct the equalization curve in the same way The only difference is the way the values are represented Copy Paste Import and Export Equalizer Channel Settings These features make it simple to use effecti...

Страница 18: ...a ble EQ Application Suggested Settings Treble boost for improved speech intelligibility Add a high shelf filter to boost frequencies greater than 1 kHz by 3 6 dB HVAC noise reduction Add a low cut fi...

Страница 19: ...esets can be stored on each device to match various seating arrangements A preset saves all device settings except for the Device Name IP Settings and Passwords Importing and ex porting presets into n...

Страница 20: ...tations see our FAQs Installation Microphone Placement Room Variables Optimal microphone placement is determined by the seating arrangements and infrastructure Follow these guidelines for the best pos...

Страница 21: ...h a cardioid gooseneck mi crophone at various distances This information is useful for predicting how the array microphone will perform at a given dis tance and to determine an ideal mounting height T...

Страница 22: ...the microphone Verify the ceiling grid size matches the appropriate model variation If using the optional junction box install it on the microphone prior to ceiling installation IMPORTANT Do not insta...

Страница 23: ...rnet cable above the ceiling grid and through the opening in the ceiling Note An optional junction box accessory model A910 JB mounts on the microphone to directly connect conduit Plug the Ethernet ca...

Страница 24: ...Incorporated 24 59 Rubber Scratch Protectors MXA910W A Optional Before installing the microphone in the ceiling attach the included rubber pads to the corners of the microphone flange to prevent scrat...

Страница 25: ...onduit Plug the Ethernet cable into the array microphone output Attach the safety tether between the building structure and one of the tie off points on the back of the microphone using braided metal...

Страница 26: ...d T bars you may need to remove or adjust one side s T bar to install the MXA910W A Rubber Scratch Protectors MXA910W US Optional Before installing the microphone in the ceiling attach the included ru...

Страница 27: ...conduit Plug the Ethernet cable into the array microphone output Attach the safety tether between the building structure and one of the tie off points on the back of the microphone using braided metal...

Страница 28: ...Shure Incorporated 28 59...

Страница 29: ...eaded hole depth 9 15 mm Hole spacing 100 mm square Hard Ceiling Mounting You can mount the microphone in hard ceilings without a tile grid using the A910 HCM accessory Learn more at www shure com Pai...

Страница 30: ...Removing the screws to detach the main assembly 1 4 1 5 Removing screws and detaching one side of the frame Step 2 Masking and Painting Use masking tape to cover the entire extrusion that runs along t...

Страница 31: ...rnet cable out of view use the appropriate method based on the installation type Installation Cable Solution Ceiling grid Run the cable above the ceiling grid VESA pole mounting Guide the cable throug...

Страница 32: ...holes in the junction box prior to installing it onto the microphone To install Remove the 4 screws from the microphone as shown Align the junction box with the screw holes If possible plug the netwo...

Страница 33: ...ether online or offline Control Shure device settings and coverage Route audio between Shure devices Push settings to many devices at once Create and reuse templates across multiple locations and proj...

Страница 34: ...s To ensure the best performance disabling hardware acceleration and unused plug ins is recommended Accessing the Web Application without the Discovery App If the Discovery application is not installe...

Страница 35: ...nel on a 3 x device and you update it to 4 x the following settings will be ap plied automatically AGC enabled AEC enabled Noise reduction enabled Compressor disabled Delay disabled New Automixer Adde...

Страница 36: ...liMix DSP 1 PoE port 2 Foot 4 individual channel outputs or 1 automix channel output with IntelliMix DSP 1 AEC reference input 4 Foot 8 individual channel outputs or 1 automix channel output with Inte...

Страница 37: ...gnals to Dante signals Converts 2 Dante signals to analog signals 2 analog in 2 analog out 1 PoE port 2 Dante inputs 2 Dante outputs MXN5 C Networked ceiling loud speaker powered by PoE 1 PoE port 2 D...

Страница 38: ...h an ANIUSB MATRIX or a P300 Computer running conferencing software connects to the ANIUSB MATRIX or P300 with a USB cable Ceiling array provides acoustic echo cancellation and DSP with firmware 4 x M...

Страница 39: ...firmware 4 x ANI22 connects analog and digital components 2 line mic inputs convert analog signals to digital 2 outputs to convert digital signals to analog Equipment List MXA910 needs firmware 4 x f...

Страница 40: ...SB and analog block in out Designer controls microphones and P300 Equipment List 2 MXA910s needs firmware 4 x for AEC P300 Network switch supplying Power over Ethernet Plus PoE Computer on network wit...

Страница 41: ...ation setting is lower and provides transparent gat ing Manual Manual mode sums all active tracks and sends the summed signal over a single Dante output This provides the option to route an individual...

Страница 42: ...mode Off attenuation settings for each channel are scaled depending on the number of open channels The scaled gain structure helps to reduce noise when there is a high channel count When fewer channe...

Страница 43: ...and stops it from being captured by the microphone to deliver clear uninterrupted speech During a conference call the AEC works constantly to opti mize processing as long as far end audio is present...

Страница 44: ...alculates the noise floor in the room and removes noise throughout the entire spectrum with maximum transparency Settings The noise reduction setting low medium or high represents the amount of reduct...

Страница 45: ...the threshold by 1 dB effectively reducing the signal by 9 dB Encryption Audio is encrypted with the Advanced Encryption Standard AES 256 as specified by the US Government National Institute of Standa...

Страница 46: ...udio Networking Dante digital audio is carried over standard Ethernet and operates using standard internet protocols Dante provides low laten cy tight clock synchronization and high Quality of Service...

Страница 47: ...IntelliMix Room 16 16 Learn more about Dante flows in our FAQs or from Audinate QoS Quality of Service Settings QoS settings assign priorities to specific data packets on the network ensuring reliable...

Страница 48: ...ices when setting up a network to ensure reliable communication Always use a star network topology by connecting each component directly to the switch or router Connect all Shure networked devices to...

Страница 49: ...onfiguration Manually Assigning Static IP Address To manually assign IP addresses follow these steps Open the device s configuration window in Designer Go to the Settings tab and select Network Select...

Страница 50: ...13 MAC address as array of 6 bytes Note The Shure device should respond in less than one second on a typical network If there is no response try sending the query again after verify ing the destinatio...

Страница 51: ...ol system to access the device through a firewall These protocols require multicast Ensure multicast has been correctly configured for your network Echo Reduction Firmware 4 x only In audio conferenci...

Страница 52: ...ff attenuation setting changes to 56 dB and the Leave last microphone on setting is set to OFF when echo reduction is enabled Using Command Strings This device receives logic commands over the network...

Страница 53: ...f Auto positioning identifies incorrect location If talker is in a corner or very close to a wall acoustic reflec tions may interfere with localization accuracy Try automatic positioning again and if...

Страница 54: ...encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connec...

Страница 55: ...3 77 x 2 15 in H x W x D control application HTML5 Browser based or Shure Designer Plenum Rating UL 2043 Suitable for Air Handling Spaces Dust Protection IEC 60529 IP5X Dust Protected Operating Temper...

Страница 56: ...ion AEC Noise Reduction Automatic Gain Control Com pressor Delay Equalizer 4 band Parametric Mute Gain 140 dBrange MXA910 firmware 3 x or older Automaticmixing Echo Reduction Equalizer 4 band Parametr...

Страница 57: ...sents where the sensitivity reaches 6 dB Understanding how lobe sensitivity is displayed helps to Provide complete coverage in a space either by adding lobes or changing the lobe width This ensures th...

Страница 58: ...eplacement Parts Junction box accessory A910 JB Hard ceiling mount A910 HCM MXA910W 60CM frame and grille assembly RPM904 MXA910AL 60CM frame and grille assembly RPM905 MXA910B 60CM frame and grille a...

Страница 59: ...Shure Incorporated 59 59 Furnished Accessories 95A28365 95A29877 Contact Customer Support Didn t find what you need Contact our customer support to get help...