10
SHENZHEN SHUNXUN ELECTRONICS CO.,LTD
www.foxun.com
120m HDMI Extender over Ethernet, with RS232, POE, IR
RS232 pass through
The TX and RX are with DE-9M connect or, TX: Female connector; RX: Mode connector.
DE-9 Male
(
Pin Side
)
DE-9 Female (Pin Side
)
------------- -------------
\ 1 2 3 4 5 / \ 5 4 3 2 1 /
\ 6 7 8 9 / \ 9 8 7 6 /
--------- ---------
RS-232 Pin Definition
TX PIN Definition PIN Definition
1 NC
2 TxD
3 RxD
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC
RX PIN Definition PIN Definition
1 NC
2 RxD
3 TxD
4 NC
5 GND
6 NC
7 NC
8 NC
9 NC
Baud Rate: 115200(Default)
Data Bit: 8 bits
Parity: None
Stop Bit: 1 bit
Flow Control: None
User can login web site to modify the Baud Rate which range from 1200 to 115200 (login in the IP
address: TX: 192.168.168.55/RX: 192.168.168.56). When sending the data, the IP address must be as
header (eg: If you need send “5A”, the IP address of transmitter is 192.168.168.55, “CO A8 A8 37” is the
Hex format of IP address 192.168.168.55, then you should send “CO A8 A8 37 5A”).