Solar working station operation manual SR881
- 13 -
Output ports
Output P1
:
For solar circuit pump and also suitable for RMP control, Semiconductor relay
(SCR relay), Max. Switching current 1A,
Output P2
:
Electromagnetic relay, its max. switching current 3.5A.
Output H1
:
For back-up electrical heater, electromagnetic relay, and max. Switching current
10A, H1 connection ports are always open.
2. Commissioning of integrated controller
Connect the sensors, pumps or switching valves to the controller before you
connect the power supply! After switching on power to the controller, firstly it will ask
for to set the time, password and parameters of system.
2.1 Set time/week
►Press “Clock” button, time displays on screen, our selection area “00” blinks on display
screen.
►Press
“+”“-”
button to set hour of clock
►Press “Clock” button again, minute area“00”blinks
►Press
“+”“-”
button to set minute of clock.
►Press “Clock” again, week area “MO” blinks
►Press
“+”“-”
button to set week.
►
Press “ESC” button to exit set program, or wait for 20 seconds to exit program
automatically.