3. Excessive dust, liquid or dirt etc on the equipment will affect performance of the machine
and cause poor heat dissipation. Remove dust with air compressor, vacuum or soft brush. Use a
damp cloth to clean the case.
4. Before storing the machine, run distilled water through the system to help avoid condensing
the pump or heater.
5. To keep the best status and performance of machine, it is recommended to running the
machine at least once per month.
6. After continuous use of 40h (or 1-2month), please use 35% vinegar with 65% distilled water
to wash the pump and pipe system by running the machine 10-15 times.
▲
Possible reason for the block of atomizer
For healthy and best status of machine, please do use SHOWVEN original fog fluid.
A. Fluid spill: heat can’t effectively transmit to fog fluid, leads to insufficient atomization of the
fog fluid in the heating pipe.
Possible Reason 1: Use other type of low quality fog fluid instead of SHOWVEN original fog
fluid.
Possible reason 2: Use inappropriate fog fluid. For different types of fog fluid, the atomization
temperature is different.
B. Heating aluminum pipe clog: early symptom for heating aluminum pipe clog is fog fluid spill
caused by insufficient atomization. Use other brand fluid or not make regular maintenance for
a long time will definitely leads to pipe clog.
C. Solution for above problem: Use SHOWVEN original fog fluid. Make regular maintenance
(every 1-2month). Use 35% vinegar with 65% distilled water to wash the pump and pipe
system by running the machine 10-15 times.