background image

10 

 

Control Panel 

When the indicator light is on, means the Gobo Quake is working 

 
 
 
 
 
 
 
 
 
     
 
 
 
 

 

 

 

 

 

 

 

 

 

Fig. 5

 

 

 

A.

 Power LED   

 

D.

 [MENU] Button 

 

G.

 [ENTER] Button 

B.

 Display 

 

 

E.

 Up Button   

 

H.

 Sound LED 

C.

 DMX LED 

 

 

F.

 Down Button 

 

 

DMX Control Mode 

The fixtures are individually addressed           

        

       on a data-link and connected to the controller.  

The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address the next time.)

 

 

DMX Addressing

 

The control panel on the front side of the Gobo Quake allows you to assign the DMX fixture address, 
which is the first channel from which the Gobo Quake will respond to the controller. 
Please note when you use the controller, the unit has 

3

 channels. 

When using multiple Gobo Quakes, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Gobo Quake should be 

1(A001)

; the DMX address of the second 

Gobo Quake should be 

1+3=4 (A004

); the DMX address of the third Gobo Quake should be 

4+3=7 

 

(A007)

, etc. Please, be sure that you don’t have any overlapping channels in order to control each 

Gobo Quake correctly. 
If two or more Gobo Quakes are addressed similarly, they will work similarly.

 

For address settings, please refer to the instructions under ”Addressing’ (menu 

)

 

 

Controlling: 

After having addressed all Gobo Quake fixtures, you may now start operating these via your lighting 
controller.

 

Note:

 After switching on, the Gobo Quake will automatically detect whether DMX 512 data is received 

or not. 

If there is 

no data received at the DMX-input, the “

LED

 “ on the control panel will not flash.

 

The problem may be:

 

- The XLR cable from the controller is not connected with the input of the Gobo Quake.

 

- The controller is switched off or defective, the cable or connector is detective, or the signal wires are    
  swapped in the input connector. 

 
Note: 

It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link. 
 
 
 
 
 

Содержание Starzone Gobo Quake DMX

Страница 1: ...Starzone Gobo Quake DMX ORDERCODE 31322...

Страница 2: ...Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you o...

Страница 3: ...ng Determinations Rigging Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One City Painter Multiple City Painters DMX Protocol DMX Channels Control Mod...

Страница 4: ...unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a...

Страница 5: ...Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service For adult use only...

Страница 6: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Страница 7: ...e mode Music Auto master slave DMX 512 3 channels 2 colour wheels 16 colours 13 colour mix 1 gobo wheel LCD Display Sound controlled via built in microphone Variable focus Lamp ELC 24V 250 Watt includ...

Страница 8: ...6 Backside 4 5 6 7 Fig 2 4 DMX signal connector OUT 5 DMX signal connector IN 6 Microphone 7 IEC Power connector Fuse...

Страница 9: ...ranty Procedure 1 Loosen the 6 screws on the back of the housing 2 Gently remove the plastic housing 3 Read lamp instructions Do not touch the lamp bulb glass See Figure 3 Oil on hands shortens the la...

Страница 10: ...ion 2 Use a 3 p XLR cable to connect the Gobo Quakes and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 4 Connect a DMX signal cable from the first unit s DMX out...

Страница 11: ...MX Mode 100 155 Automatic Program 156 255 Sound Activity Mode Channel 2 Colorwheel Rotation 0 No Rotation 1 99 Clockwise rotation from slow to fast 100 155 Stop Rotation 156 255 Counterclockwise rotat...

Страница 12: ...ss of the second Gobo Quake should be 1 3 4 A004 the DMX address of the third Gobo Quake should be 4 3 7 A007 etc Please be sure that you don t have any overlapping channels in order to control each G...

Страница 13: ...too You can t play or edit any program on a slave if the master is switched on and connected to the master slave chain Note Disconnect the fixtures from the DMX controller before master slave operatin...

Страница 14: ...al fatigue The Showtec Gobo Quake requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantly reduced Disconnect the mains power su...

Страница 15: ...come out 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same typ...

Страница 16: ...ELC 24V 250W 3400 K 50 hr ordercode 80809S Electro mechanical effects Max ambient temperature ta 55 C Max housing temperature tB 80 C Cooling 1 axial fan in the projector Minimum distance Minimum dis...

Страница 17: ......

Отзывы: