DMX Channels 

 

10 Channels

 

 
Channel 1 – Colors, Program  Mode and Sound Active Mode  

 

0-14 

Blackout 

15-19 

Red 

20-24 

Green 

25-29 

Blue 

30-34 

Red + Green 

35-39 

Red + Blue 

40-44 

Green +  Blue 

45-49 

Red + Green + Blue 

50-199 

Program Mode (Select Program with CH2)  

200-255 

Sound-controlled 

 

Channel 2 – Built-in programs (Only works when CH1 is set between 50-199         ) 

 

0-7 

Built-in Program 1 

8-15 

Built-in Program 2

 

16-23 

Built-in Program 3

 

24-31 

Built-in Program 4

 

32-39 

Built-in Program 5

 

40-47 

Built-in Program 6

 

48-55 

Built-in Program 7

 

56-63 

Built-in Program 8

 

64-71 

Built-in Program 9

 

72-79 

Built-in Program 10

 

80-87 

Built-in Program 11

 

88-95 

Built-in Program 12

 

96-103 

Built-in Program 13

 

104-111

 

Built-in Program 14

 

112-119

 

Built-in Program 15

 

120-127

 

Built-in Program 16

 

128-135

 

Built-in Program 17

 

136-143

 

Built-in Program 18

 

144-151

 

Built-in Program 19

 

152-159

 

Built-in Program 20

 

160-167

 

Built-in Program 21

 

168-175

 

Built-in Program 22

 

176-183

 

Built-in Program 23

 

184-191

 

Built-in Program 24

 

192-199

 

Built-in Program 25

 

200-207

 

Built-in Program 26

 

208-215

 

Built-in Program 27

 

216-223

 

Built-in Program 28

 

224-231

 

Built-in Program 29

 

232-239

 

Built-in Program 30

 

240-247

 

Built-in Program 31

 

248-255

 

Built-in Program 32

 

 

Channel 3 – Speed (Only works when CH1 is set between 50-199         ) 

 

0-255 

Speed from slow to fast 

 
Channel 4 – LED movement 1 (Only works when CH1 is set between 50-199         ) 

 

0-255 

Up to down equalizer effect from slow to fast 

 

 

Содержание Spider LED

Страница 1: ...Spider LED ORDERCODE 43107 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you o...

Страница 3: ...Control Modes 7 One Spider LED Auto Run Programs 7 One Spider LED Sound control 8 Multiple Spider LEDs Master Slave control 8 Multiple Spider LEDs DMX Control 9 Fixture Linking 10 Data Cabling 10 Dips...

Страница 4: ...s will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include clim...

Страница 5: ...that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the external c...

Страница 6: ...tallation yourself Always let the installation be carried out by an authorized dealer Procedure If the Spider LED is lowered from the ceiling or high joists professional trussing systems have to be us...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...Peak Power 63 Watt Continuous Power 45 Watt Control Auto Run Sound Master Slave DMX Sound active program selectable by DMX Music controlled via built in microphone DMX Channels 10 Powerconnector IEC...

Страница 9: ...to Run Programs 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Plug the end of the electric mains power cord into a proper electric power supp...

Страница 10: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Plug the end of the electric mains power cord into a proper electric power supply socket 3...

Страница 11: ...g with the first unit Do not supply power before the whole system is set up and connected properly Multiple Spider LEDs DMX Set Up Fig 3 Note Link all cables before connecting electric power Controlli...

Страница 12: ...ter may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Spider LEDs on a DMX data link 30 fixtures Data Cabling To...

Страница 13: ...Explanation Since each unit has 10 channels each address advances 10 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate address DMX D...

Страница 14: ...12 DMX Quick Reference Chart...

Страница 15: ...ogram 11 88 95 Built in Program 12 96 103 Built in Program 13 104 111 Built in Program 14 112 119 Built in Program 15 120 127 Built in Program 16 128 135 Built in Program 17 136 143 Built in Program 1...

Страница 16: ...upplying electric power The operator has to make sure that safety relating and machine technical installations are to be inspected by an expert after every four years in the course of an acceptance te...

Страница 17: ...4 If all of the above appears to be O K plug the unit in again 5 If you are unable to determine the cause of the problem do not open the Spider LED as this may damage the unit and the warranty will be...

Страница 18: ...ect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture o...