Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The maximum ambient temperature 

t

a

 = 35°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 35° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others!

 

 
 

Connection with the Three Phase Power Network

 

Connect the device to the 3-phase Power Socket with a CEE-form power-plug. 
Always make sure that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

L1 

BROWN

 

RED

 

BLACK

 

PHASE 1

 

L2 

BLACK 

YELLOW 

RED 

PHASE 2 

L3 

GREY 

BLUE 

BLUE 

PHASE 3 

BLUE 

BLACK 

WHITE 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

Improper installation can cause serious injuries to people and/or damage of property ! 

 

 

Содержание PSA-125A4C

Страница 1: ...PSA 125A4C V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50667 MANUAL ENGLISH...

Страница 2: ...uctions 2 Operating Determinations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Frontside 7 Backside 8 Installation 9 Set Up and...

Страница 3: ...ox and packing Your shipment includes Showtec PSA 125A4C User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow...

Страница 4: ...exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and...

Страница 5: ...d Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Connection with the Three Phase Power Network Connect...

Страница 6: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Страница 7: ...V AC 50 60Hz Output 4 x CEE female 63A 3P N PE 400V AC 50 60Hz 4 x 3 pin 63A C Type MCB 1 x 4 pin 125A C Type main circuit breaker Rated current 125A Tripping curve MCB C type Poles 4P Breaking capaci...

Страница 8: ...Main Circuit Breaker MCB This circuit breaker will cut off the power supply if the load current per phase exceeds 63A 06 Output 2 Main Circuit Breaker MCB This circuit breaker will cut off the power...

Страница 9: ...t 3 3P N PE CEE socket maximum load 3 x 63A per socket Total load for all 4 sockets together should not exceed 125A per phase 12 CEE Output 4 3P N PE CEE socket maximum load 3 x 63A per socket Total l...

Страница 10: ...owing points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be a...

Страница 11: ...pe main circuit breaker Output MCB 4 x 3 pin 63A C Type Electro mechanical effects IP rating IP20 Housing Powder coated metal Rated current 125A Breaking capacity 10kA Color Dark grey Voltage and ampe...

Страница 12: ...2016 Showtec...

Отзывы: