13
Maintenance
The operator has to make sure that safety-relating and machine-technical installations are to be inspected
by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be inspected
by a skilled person once a year.
The following points have to be considered during the inspection:
1.
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2.
There may not be any deformations on housings, fixations and installation spots.
3.
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4.
The electric power supply cables must not show any damages or material fatigue.
The Showtec
Multi Profile Spot
requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the light-output will be significantly reduced.
Disconnect the mains power supply, and then wipe
the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and a soft cloth.
Do not use alcohol or solvents.
The front glass will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly.
Please clean internal components once a year with a light brush and vacuum cleaner.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections with a
damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.
Changing the Lamp
1.
Disconnect mains power supply, and allow 15 minutes to cool down.
2.
Loosen the knurled bolt on the back of the lamp housing and pull the housing out.
3.
Holding it by the base, remove the lamp from its retention box.
4.
Follow directions for installing a new lamp, page 6.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates
properly, do not carry out following steps.
1.
If the device does not operate properly, unplug the device.
2.
Check the fuse, power from the wall, all cables etc.
3.
If all of the above appears to be O.K., plug the unit in again.
4.
If you are unable to determine the cause of the problem, do not open the device, as this may damage the
unit and the warranty will become void.
5.
Return the device to your Showtec dealer.
No Light
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps
below in sequence until a solution is found. Once the unit operates properly, do not carry out following
steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect two potential problem areas: the power supply or the lamp.
1.
Power supply. Check that the unit is plugged into an appropriate power supply.
2.
The lamp. Replace the old lamp with a new one with the same specifications. See page 10 for replacing
the lamp.