background image

 

      Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

   

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание LED Roto Flower

Страница 1: ...LED Roto Flower ORDERCODE 43032...

Страница 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...turn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX Mo...

Страница 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may incl...

Страница 5: ...ble voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces ca...

Страница 6: ...on yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Roto Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...ue 36 Beam angle 15 6 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 Fig...

Страница 9: ...rom electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON Automatic...

Страница 10: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the DJ LED Flower The pins 1 Earth 2 Signal 3 Signal 3 Link...

Страница 11: ...DMX dip switches as follows See Dip Switch setting page 10 On the Master device Dipswitch 9 must be set to ON On all slave devices Dipswitch 9 must be set to OFF LED Roto Flower Address Value DMX Dip...

Страница 12: ...tches ON Unit 5 25 1 4 5 Switch Value 1 1 4 8 5 16 Total sum 25 Explanation Since each unit has 6 channels each address advances 6 values See Address Value above Once address values are determined add...

Страница 13: ...11...

Страница 14: ...re s light output will be significantly reduced Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth...

Страница 15: ...s If not take the controller in for repair If so take the DMX cable and the light effect to a qualified technician Problem Probable cause s Remedy One or more fixtures are completely dead No power to...

Страница 16: ...ration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 238 x 216 mm Weight 3 6 kg Minimum distance Minimum distance from...

Страница 17: ......

Отзывы: