SHOWTEC LED Imagespot 75W Скачать руководство пользователя страница 11

 

  

 

 

10 

   

 

Ordercode: 40713 

 

LED Imagespot 75W 

Multiple LED Imagespots 75W Set Up 
 

 

Fig. 02 

Note : Link all cables before connecting electric power 

 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512  controller or to 
run synchronized  shows of two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.  
 

Important: 

Fixtures on a serial data link must be daisy-chained  in a single line. To comply with the  
EIA-485  standard, no more than 14 devices should be connected on one data link. 
Connecting more than 14 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal.  

 

Maximum recommended  DMX data link distance: 100 meters 
Maximum recommended  number of fixtures on a DMX data link: 14 fixtures 
Maximum recommended  number of fixtures on a Power link: 14 fixtures 

 

Data Cabling 

To link fixtures together, you must obtain data cables. You can purchase  DAP Audio  certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create  your own cable, 
please use data-grade cables that can carry  a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio DMX Data Cables 

 

DAP  Audio  Basic  microphone  cable  for allround  use.  bal. XLR/M 3-pin > XLR/F 3-pin. 

Ordercode

 

FL01150  (1,5 m), FL013  (3 m), FL016 (6 m), FL0110  (10 m), FL0115  (15 m), FL0120  (20 m). 

 

DAP  Audio  X-type  data cable  XLR/M  3-pin  > XLR/F  3-pin. 

Ordercode

  FLX0175  (0,75  m), 

FLX01150  (1,5  m), FLX013  (3 m), FLX016  (6 m),  FLX0110  (10  m). 

 

DAP  Audio  cable  for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL71150  (1,5 m), FL713  (3 m), FL716 (6 m), FL7110  (10 m). 

 

DAP  Audio  cable  for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL7275  (0,75 m), FL72150  (1,5 m), FL723 (3 m), FL726 (6 m), FL7210  (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. 

Ordercode

 FL0975  (0,75 m), 

FL09150  (1,5 m), FL093  (3 m), FL096 (6 m), FL0910  (10 m), FL0915  (15 m), FL0920  (20 m). 

 

DAP Audio DMX adapter: 3-pin/5-pin. 

Ordercode

 FLA30. 

 

Содержание LED Imagespot 75W

Страница 1: ...LED Imagespot 75W V1 Highlit e Int ernat ional B V Vest ast raat 2 6468 EX K erkrade t he Net herlands Ordercode 40713 MANUAL ENGLISH...

Страница 2: ...mode 9 Multiple LED Imagespots 75W DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 12 DMX Addressing 13 Manual m...

Страница 3: ...Your shipment includes Showtec LED Imagespot 75W IEC Cable 0 9m 4 x framing shutters User manual Safety Instructions Every person involved with the installation operation and maintenance of this devi...

Страница 4: ...evice is not used or before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust...

Страница 5: ...lectric shock crash etc You endanger your own safety and the safety of others Rigging Please follow t he European and nat ional guidelines concerning rigging trussing and all ot her safetyissues Do no...

Страница 6: ...ir or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of pa...

Страница 7: ...standard or personalized round and square shaped gobos DMX control Temp controlled fan 14 22 Zoom range Framing shutters Accepts round square gobos Input Voltage 100 240VAC 50 60Hz Fuse F3AL 250V Pow...

Страница 8: ...r not included 04 Power IEC IN 05 Ground Earth connection 06 Power IEC OUT max 14 links 07 DMX signal connector OUT 5 pin 08 DMX signal connector IN 5 pin 09 Gobo compartment cover with fastening scre...

Страница 9: ...ions below as they pertain to your preferred operation mode Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120...

Страница 10: ...e see page 13 for more information about the Manual mode Multiple LED Imagespots 75W DMX Control 01 Fasten the effect light to a firm trussing Leave at least 0 5 meter on all sides for air circulation...

Страница 11: ...wer link 14 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable I...

Страница 12: ...t 75W should be 1 4 5 05 the DMX address of the third LED Imagespot 75W should be 5 4 9 009 etc Please be sure that you do not have any overlapping channels in order to control each LED Imagespot 75W...

Страница 13: ...12 Ordercode 40713 LED Imagespot 75W Menu Overview Main Menu Options DMX address Manual mode Display setting Temperature Reset system Reset factory settings...

Страница 14: ...use the UP DOWN buttons to set the speed between 08 When the display shows you can set the intensity of the color Press the ENTER button to open this menu and use the UP DOWN buttons to set the intens...

Страница 15: ...to the main menu Color wheel adjustment from 000 255 Dimmer intensity from 000 255 Temperature protection setting Color wheel adjustment With this menu option you can adjust the color wheel 01 Press t...

Страница 16: ...e set between 001 255 and CH2 between 004 007 or 216 255 0 6 White 7 13 Yellow 14 20 Pink 21 27 Green 28 34 Red 35 41 Light blue 42 48 Light green 49 55 Orange 56 63 Dark blue 64 70 Split colors White...

Страница 17: ...ow the directions below 01 Unplug the unit from electric power source 02 Insert a flat headed screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a...

Страница 18: ...tions and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link...

Страница 19: ...Dimmer 0 100 Strobe 0 20Hz Housing Black Metal Flame retardant plastic DMX control via standard DMX controller On Board 4 digit LED display for easy setup Control Manual and DMX Power Connections IEC...

Страница 20: ...19 Ordercode 40713 LED Imagespot 75W Dimensions...

Страница 21: ...20 Ordercode 40713 LED Imagespot 75W Notes...

Страница 22: ...21 Ordercode 40713 LED Imagespot 75W...

Страница 23: ...22 Ordercode 40713 LED Imagespot 75W...

Страница 24: ...2016 Showtec...

Отзывы: