6
5.
Put in the new lamp securely into the socket. Please note the protuberance of bulb shall be upward
orientation to obtain equal intensity distribution (see figure2).
Fig. 2
6.
Fasten
the 2 thumb screws and reassemble the device in reverse order.
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
Two low voltage electrified guides (24 V) with short-circuit protection are equipped with this fixture to accept
the user's choice of lens unit and optional accessories for different effects and various combinations. The
effects can be either static or motorized for stationary and moving images.
Fig. 3
Warning
Never disconnect or reconnect the power frequently during operation, this will shorten the lamp life.
Wait at least 10 minutes to cool down the lamp completely before restarting this unit. (the warm lamp will
cause the igniter holding the lamp in a glow state.)
Lens Focusing
1.
Hang the fixture in your final desired position.
2.
Loosen the thumb screw fitted in the lens support that hold the lens in place.
3.
Adjust the lens by turning it in a clockwise or counter-clockwise direction until you reach proper focus.
4.
Tighten the thumb screw after you achieve your desired focus.