3

  Avoid flames and do not put close to flammable liquids or gases.

  Always replace the lamp, when it is damaged or deformed due to the heat.

  Always keep case closed while operating.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning or when

replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the
power-cord.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to

cracks or deep scratches.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. Light effect must be installed out of the reach of children. Never leave the unit

running unattended.

  For replacement use lamps and fuses of same type and rating only.

  Allow time to cool down, before replacing lamp.

  This device is only allowed for an installation via the mounting bracket.

  The user is responsible for correct positioning and operating of the Image Spot. The manufacturer

will not accept liability for damages caused by the misuse or incorrect installation of this device.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  During the initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

OPERATING DETERMINATIONS

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device
will serve you for a long time without defects.

The minimum distance between light-output and the illuminated surface must be more than 0,5 meters.

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded.

The relative humidity must not exceed 50 % with an ambient temperature of 45° C.

If this device is operated in any other way, than the one described in this manual, the product may suffer
damages and the

 

warranty becomes void.

Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash etc.

You endanger your own safety and the safety of others!

CAUTION ! EYEDAMAGES !.

Avoid looking directly into the light source.

(meant especially for epileptics) !

Содержание ImageSpot 300

Страница 1: ...ImageSpot 300 ORDERCODE 40707...

Страница 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...ning Safety instructions Operating Determinations Rigging Description Features and Overview Installation Installing the Lamp Set Up and Operation Lens Focusing Maintenance Changing the Lamp Replacing...

Страница 4: ...se anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge lamps may expose and emit a high ultravi...

Страница 5: ...out of the reach of children Never leave the unit running unattended For replacement use lamps and fuses of same type and rating only Allow time to cool down before replacing lamp This device is only...

Страница 6: ...swinging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make...

Страница 7: ...roduct versions that use other lamps may be offered in the future Check your product specification label for information Always disconnect from electric mains power supply before changing lamps The la...

Страница 8: ...e equipped with this fixture to accept the user s choice of lens unit and optional accessories for different effects and various combinations The effects can be either static or motorized for stationa...

Страница 9: ...The front PC lens will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly Please clean internal components once a year with a light brush and vacu...

Страница 10: ...t the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technician R...

Страница 11: ...tion of rotating gobo with static gobo for different effects Thanks to the use of standard sized gobos customers can also purchase gobos from other manufactures By using several accessories together y...

Страница 12: ...or glass 65 mm Maximum image diameter 36 mm One fixed gobo holder 6 metal gobos Max ambient temperature ta 40 C Max housing temperature tB 80 C Extra s ISP 1 ordercode 40708 ISP 2 ordercode 40709 Min...

Страница 13: ...2007 Showtec...

Отзывы: