background image

 

  

 

 

   

 

Order code: 41166 

Illumilift RGBW Turbo 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always check if the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

PHASE 

BLUE 

BLACK 

SILVER 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always properly connected to the earth! 

 

Improper installation can cause serious injuries and/or damage of property! 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery. 
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
agreed otherwise in writing. 
Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of 
the invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement from which the obligation is resulting. 
 

 

Содержание Illumilift RGBW Turbo

Страница 1: ...Illumilift RGBW Turbo V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 41166 MANUAL ENGLISH...

Страница 2: ...tup and Operation 9 Control Modes 10 One Illumilift Manual 10 Multiple Illumilifts DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13...

Страница 3: ...ts to ensure that all parts are present and have been received in good condition Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or t...

Страница 4: ...EDs Never look directly into the light source Never leave any cables lying around Never use the device during thunderstorms unplug the device immediately Never leave various parts of the packaging pla...

Страница 5: ...ly in the original packing material and return it to your Showtec dealer for service For adult use only The device must be installed beyond the reach of children Never leave the unit running unattende...

Страница 6: ...inging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or a safety cable that can hold a minimum point load of 10 times the device s l...

Страница 7: ...roper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your a...

Страница 8: ...nnel Refresh rate 19 6 kHz Dimmer 0 100 Strobe 0 20 Hz DMX control via standard DMX controller DMX channels 6 10 channels Control Manual DMX 512 Housing Metal flame retardant plastic Cooling Cooling f...

Страница 9: ...DMX signal connector OUT 05 3 pin DMX signal connector IN 06 Power switch ON OFF 07 100 240 V pro power connector IN Blue 08 100 240 V pro power connector OUT Gray 09 Ground earth connection 10 Fuse...

Страница 10: ...rtical position and or the LED sphere is not installed it may result in twisting of the cable that may cause damage to the built in winch system and the warranty will become void Before powering the I...

Страница 11: ...ht to a firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Use a 3 pin XLR cable to connect the Illumilifts and other devices...

Страница 12: ...a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interfe...

Страница 13: ...is not interrupted in any way Control Panel A LED display B MENU button C UP button D DOWN button E ENTER button Fig 05 Control Mode The fixtures are individually addressed on a data link and connect...

Страница 14: ...the controller is not connected with the input of the Illumilift RGBW Turbo The controller is switched off or defective the cable or connector is detective or the signal wires are swapped in the inpu...

Страница 15: ...n manually set the desired colors 01 In main menu press the MENU button until the display shows 02 Press the ENTER button to toggle through the following options Red LED brightness from dark to bright...

Страница 16: ...05 111 Color 15 R255 G000 B100 W000 112 118 Color 16 R255 G000 B025 W000 119 125 Color 17 R000 G000 B000 W255 126 132 Color 18 R255 G255 B255 W255 133 139 Color switch 1 140 146 Color switch 2 147 153...

Страница 17: ...must be open 0 255 Gradual adjustment White from dark to brightest Channel 6 Strobe CH1 must be open CH2 5 must be open 0 10 Not functional 11 255 Strobe flash frequency from OFF to highest frequency...

Страница 18: ...inking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will...

Страница 19: ...ond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing...

Страница 20: ...oad 2 kg Lifting height 6 m Lifting speed 0 2 5 m s Lifting cable 5 x 0 5 mm2 Power on cable 4 channels max 18 V DC max 0 3A per channel Refresh rate 19 6 kHz Housing Metal flame retardant plastic DMX...

Страница 21: ...20 Order code 41166 Illumilift RGBW Turbo Dimensions...

Страница 22: ...21 Order code 41166 Illumilift RGBW Turbo Notes...

Страница 23: ...22 Order code 41166 Illumilift RGBW Turbo...

Страница 24: ...2019 Showtec...

Отзывы: