17
Stand-Alone / Slave addressing
Note: Disconnect the fixtures from the DMX controller before master/slave operating, otherwise data
collisions can occur and the fixtures will not work properly!
It’s necessary to insert the XLR termination plug (with 120 Ohm ) into the input of the master fixture and
into the output of the last slave fixture in the data-link, in order to ensure proper transmission on the data
link.
From the master’s control panel it is possible to control any slave in a master/slave chain.
1)
Press the Mode button, until the display shows Run. Press enter and then use the Up/ Down button.
The master should be set to PR6.1 or PR6.2 and the slaves should be set to SLAE
.
2)
Only one fixture can be the master. Up to the 16 slaves may be connected to the master.
Stand-alone operation” can be applied to a single fixture (the fixture may be set to the master/slave mode or
controller mode) or to multiple fixture operating synchronously.
For synchronous operation of multiple fixtures the fixtures must all be connected on a data-link and one of
them is set as a master (PR6.1 or PR6.2) and the rest as slaves (SLAE). The DMX address of all the slaves
are assigned to
and on that particular slave address only one fixture can be connected. To the fixture
as the master or slave, see “Addressing” (menu
).
If the master fixture resets or runs a test (program), all slaves will execute these acts too.
You can’t play or edit any program on a slave, if the master is switched on and connected to the
master/slave chain.
Addressing
With this menu you can set the DMX address.
- DMX addressing
1)
Press Mode until the display shows Run, then press enter. Press the Up / Down button until the display
shows DNCO and then press Enter.
2)
Press Up / Down to select the required address
, press Enter
to confirm.
3)
Press Choose
, t
he chosen address is shown on the display.