Set Up and Operation

Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.

One Explorer

1. 

Fasten the moving head onto firm trussing (Use a clamp (ordercode 70351 / 70308 / 70322) fastened

    onto the Explorer ). Leave at least 1 meter on all sides for air circulation.

2. 

Always use a safety cable (ordercode 70140 / 70141).

3. 

Plug one end of the electric mains power cord into the IEC socket on the unit

.

    Then plug the other end of the cord into a proper electric power supply socket.

4. 

To set the program to be played, by pressing the Mode button until the display shows RUN,

    then select UP. If the display shows PRG then select Enter

.

Multiple Explorers

1. 

Fasten the moving head onto firm trussing (Use a clamp (ordercode 70351 / 70308 / 70322) fastened

    onto the Explorer ). Leave at least 1 meter on all sides for air circulation.

2. 

Always use a safety cable (ordercode 70140 / 70141).

3. 

Use a 3-p XLR cable to connect the Explorers and other devices.

    The pins:

1.

Earth

2.

Signal -

3.

4.

 Link the units as shown in (figure 6), Connect a DMX signal cable from the first unit's DMX "out" socket to

    the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.

5.

 Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the other

    end of the mains power cord into proper electric power supply sockets, starting with the first unit. Do not
    supply power before the whole system is set up and connected properly.

Multiple Explorers Set Up

DMX-Set up

Master/Slave Set up

Fig. 6

Note : Link all cables before connecting electric power

Содержание Explorer 250 Wash

Страница 1: ...Explorer 250 Wash ORDERCODE 40178...

Страница 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...nd Overview Backside Installation Installing the Lamp Lamp Adjustment Beam Angle Set Up and Operation One Explorer Multiple Explorers Master Slave mode DMX Protocol Control Panel Control Mode DMX addr...

Страница 4: ...informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge...

Страница 5: ...ortation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to wor...

Страница 6: ...ceiling or high joists professional trussing systems have to be used Use a clamp to mount the projector with the mounting bracket to the trussing system The projector must never be fixed swinging free...

Страница 7: ...with the power plug Always pay attention that the right color cable is connected to the right place Wire Color Pin International Brown Fase Live L Blue Nul Neutral N Yellow Green Earth Ground Make sur...

Страница 8: ...lter and Beam shape DMX control via standard DMX controller 16 DMX control channels required Mechanical Dimmer Shutter Strobe Strobe effect with adjustable speed 1 10 flashes sec Linear electric focus...

Страница 9: ...7 Backside 3 4 5 6 Fig 2 3 DMX signal connector OUT 4 DMX signal connector IN 5 IEC power connector 6 Fuse...

Страница 10: ...due to the heat Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warrant...

Страница 11: ...ray of light must be centered Turn in addition screw B and C If the Hot Spot appears too bright you can weaken its intensity by moving the lamp closer to the reflector Turn in addition screw A until t...

Страница 12: ...10 Beam Angle...

Страница 13: ...lect UP If the display shows PRG then select Enter Multiple Explorers 1 Fasten the moving head onto firm trussing Use a clamp ordercode 70351 70308 70322 fastened onto the Explorer Leave at least 1 me...

Страница 14: ...The head can be turned by 530 and stopped at any position you wish Channel 2 Vertical movement Tilt Push the slider up in order to move head vertically TILT Gradual head adjustment from one end of the...

Страница 15: ...o slow 255 Channel 12 CMY Color effect wheel 0 7 Open White 8 15 Color 1 16 23 Color 2 24 31 Color 3 32 39 Color 4 40 47 Color 5 48 55 Color 6 56 63 Color 7 64 71 Color 8 72 79 Color 9 80 87 Color 10...

Страница 16: ...hutter open 64 95 Strobe effect from slow to fast 0 10 flashes sec 96 127 Shutter open 128 159 Pulse effect 1 in sequences from slow to fast 160 191 Shutter open 192 223 Random strobe effect from slow...

Страница 17: ...xplorer should be 1 16 17 A017 the DMX address of the third Explorer should be 17 16 33 A033 etc Please be sure that you don t have any overlapping channels in order to control each Explorer correctly...

Страница 18: ...eel can be positioned between two adjacent colours in any position It is also possible to rotate the colour wheel continuously at different speeds Shutter Dimmer Strobe The dimming 0 100 is provided b...

Страница 19: ...e fixture the fixture may be set to the master slave mode or controller mode or to multiple fixture operating synchronously For synchronous operation of multiple fixtures the fixtures must all be conn...

Страница 20: ...ables must not show any damages or material fatigue The Showtec Explorer requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantl...

Страница 21: ...de is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the li...

Страница 22: ...ss setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly...

Страница 23: ...er 5600 K and 3200 K UV Effect wheel with Frost filter and Beam shape Safety protection Every safety standard IP20 protection grade All lenses are anti reflection coated High luminous efficiency parab...

Страница 24: ...2006 Showtec...

Отзывы: