background image

 

  

 

 

   

 

Ordercode: 44110 

EventBAR 12/3 

Operating Determinations 

 

This device is not designed for permanent operation. Regular operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be bigger than 1 
meter. 

 

The maximum ambient temperature ta = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40° C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others

 

Rigging 

Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself! 
Always let the installation be carried out by an authorized dealer! 

 

Procedure

 

If the EventBAR 12/3 is lowered from the ceiling or high joists, professional trussing systems have to 
be used. 

 

Use a clamp to mount the EventBAR 12/3, with the mounting-bracket, to the trussing system. 

 

The EventBAR 12/3  must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the EventBAR 12/3, always make sure, that the area below 
the installation place is blocked and staying in the area is forbidden.

 

 
 

 
 

 

Содержание eventbar 12/3

Страница 1: ...EventBAR 12 3 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 44110 MANUAL ENGLISH...

Страница 2: ...ltiple EventBARs Wireless DMX Control 13 Connect the EventBAR 12 3 to the Wireless DMX signal transmitter 14 Disconnect from the Wireless DMX signal transmitter 14 Fixture Linking 15 Data Cabling 15 C...

Страница 3: ...2 Ordercode 44110 EventBAR 12 3 Product Specifications 27 Dimensions 28 Notes 29...

Страница 4: ...exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If...

Страница 5: ...he plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on th...

Страница 6: ...ns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do...

Страница 7: ...he mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPE...

Страница 8: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Страница 9: ...and vertical 16 Colormixing RGB Colour range 16 7 million additive colors LED source 12 x 3 in 1 RGB LEDs Power Supply 100 240V AC 50 60Hz Drive current 350 mA Refresh rate 7 8 KHz Control Mode DMX51...

Страница 10: ...in 1 RGB LEDs Backside Fig 02 03 DMX signal connector OUT 3 pin XLR XX HD female 04 Wireless DMX receiving antenna 05 Adjustment screw mounting bracket for Truss mounting 06 Adjustment screw for posi...

Страница 11: ...cification product on 230V power or vice versa Connect the device to the main power supply Charging the built in battery 01 In order to charge the battery you ll have to use the included power cable 0...

Страница 12: ...is set to or then the fixture will play one of its built in programs or show its auto run mode Please see page 20 for more information about the Built in Programs or Auto Run mode Multiple EventBARs M...

Страница 13: ...vices 05 Link the units as shown in Fig 05 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units 06 Supp...

Страница 14: ...blinking the fixture is searching for a connection 03 Connect the transmitter with multiple EventBARs In order to create a Wireless match please check the manual of your wireless signal transmitter 0...

Страница 15: ...then dim for 100ms The LED will flicker quickly 03 Communication with an emitter but no DMX data The LED Indicator will light up for 900ms and then dim for 100ms The LED will flicker slowly When the...

Страница 16: ...data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin X...

Страница 17: ...ing channels in order to control each EventBAR correctly If two or more EventBARs are addressed similarly they will work similarly Controlling After having addressed all EventBARs you may now start op...

Страница 18: ...17 Ordercode 44110 EventBAR 12 3 Menu overview...

Страница 19: ...operly In master slave mode the master fixture can execute the built in programs all the slave fixtures will work the same When operating the master slave chain you can identify the master fixture fro...

Страница 20: ...UP and DOWN buttons to set the values of each individual color from 000 255 You can combine Red Green and Blue to create an infinite range of colors 4 Power Mode With this menu you can see the energy...

Страница 21: ...he device until the display shows 02 You can choose 9 built in programs by pressing the UP and DOWN buttons 03 If you choose and you press SETUP you can choose between 9 programs and Off with the UP a...

Страница 22: ...ode Sound controlled Mode Activate Sound controlled mode Speed Mode Activate Speed mode Strobe Mode Activate Strobe mode Dimming Mode Activate Dimming Mode Plus Increase button Minus Decrease button R...

Страница 23: ...an choose between by using the and buttons 05 You can also set the strobe of the program by pressing the button 06 With the and buttons you can set the strobe between Note You can set only the strobe...

Страница 24: ...set between 1 255 0 No function 1 30 Program 01 31 61 Program 02 62 92 Program 03 93 123 Program 04 124 154 Program 05 155 185 Program 06 186 216 Program 07 217 247 Program 08 248 255 Program 09 Chann...

Страница 25: ...t be set between 1 255 0 255 Gradual adjustment Blue from 0 100 Channel 4 Dimmer 0 255 Gradual adjustment from dark to brightest 0 100 Channel 5 Shutter Strobe CH1 CH2 CH3 or CH4 must be set between 1...

Страница 26: ...DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting No Light This troubleshooting guide is meant...

Страница 27: ...e fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug I...

Страница 28: ...tal 22 and vertical 16 Max distance 10m Dimmer 0 100 Strobe 0 20Hz Color Range RGB 16 7 million additive colors Cooling convection Display LED display Housing Die Cast aluminum powder coat finish IP r...

Страница 29: ...28 Ordercode 44110 EventBAR 12 3 Dimensions...

Страница 30: ...29 Ordercode 44110 EventBAR 12 3 Notes...

Страница 31: ...30 Ordercode 44110 EventBAR 12 3...

Страница 32: ...2016 Showtec...

Отзывы: