background image

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 0.5 meter. 

 

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 
 

You endanger your own safety and the safety of others! 

 

Rigging 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the DB-1-8 is lowered from the ceiling or high joists, professional trussing systems have to be used. 

 

Use a clamp to mount the DB-1-8, with the mounting-bracket, to the trussing system. 

 

The DB-1-8 must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

Improper installation can cause serious damage to people and property !

 

 

 

Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place.

 

 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

 

Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 

 

 

Содержание DB-1-8

Страница 1: ...DB 1 8 ORDERCODE 50783 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Страница 3: ...terminations 4 Rigging 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Installation 7 Set Up and Operation 7 DMX Setup Example 7 Fixture Linking 9 Data Cabling 9 Maintenance 10 Re...

Страница 4: ...will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climat...

Страница 5: ...ot higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the...

Страница 6: ...he installation yourself Always let the installation be carried out by an authorized dealer Procedure If the DB 1 8 is lowered from the ceiling or high joists professional trussing systems have to be...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...tter Additional thru output 3 pin and 5 pin for linking to other Data Streams Electrical isolation between input and output 19 inch device 1U 1HE rack mount AC power Auto switching 100V 240V 50 60Hz D...

Страница 9: ...fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support DMX Setup E...

Страница 10: ...no data received at the DMX input the problem may be The XLR cable from the controller is not connected with the input of the first fixture The controller is switched off or defective the cable or con...

Страница 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of movingheads on a single DMX data link 32 fixtures Data Cabling...

Страница 12: ...nsert a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or...

Страница 13: ...d connect them directly together Have the defective fixture serviced by a qualified technician Lamps cuts off sporadically Possible bad lamp or the fixture is overheating Lamp may be at the end of its...

Страница 14: ...10 nut on the rear end of the unit It has clear LEDs to show the DMX signal status of each output and input Universal DMX 512 optical splitter Additional thru output 3 pin and 5 pin for linking to oth...

Страница 15: ......

Отзывы: