IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never leave various parts of the packaging (plastic bags, polystyrene foam, nails, etc.) within 
children’s reach, as they are potential sources of danger. 

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device. 

 

Do not connect this device to a dimmerpack. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes hot). 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the device after having familiarized with its functions. 

 

Only install the device with the hanging-bracket. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that no side forces can impact on the truss system. 

 

The cable insert or the female part in the device must never be strained. There must always be 
sufficient cable to the device. Otherwise, the cable may be damaged which may lead to deadly 
electrical shocks. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the DB-1-8. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

For replacement use fuses of same type and rating only. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 
 

 
 

 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание DB-1-8

Страница 1: ...DB 1 8 ORDERCODE 50783 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Страница 3: ...terminations 4 Rigging 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Installation 7 Set Up and Operation 7 DMX Setup Example 7 Fixture Linking 9 Data Cabling 9 Maintenance 10 Re...

Страница 4: ...will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climat...

Страница 5: ...ot higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the...

Страница 6: ...he installation yourself Always let the installation be carried out by an authorized dealer Procedure If the DB 1 8 is lowered from the ceiling or high joists professional trussing systems have to be...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...tter Additional thru output 3 pin and 5 pin for linking to other Data Streams Electrical isolation between input and output 19 inch device 1U 1HE rack mount AC power Auto switching 100V 240V 50 60Hz D...

Страница 9: ...fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support DMX Setup E...

Страница 10: ...no data received at the DMX input the problem may be The XLR cable from the controller is not connected with the input of the first fixture The controller is switched off or defective the cable or con...

Страница 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of movingheads on a single DMX data link 32 fixtures Data Cabling...

Страница 12: ...nsert a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or...

Страница 13: ...d connect them directly together Have the defective fixture serviced by a qualified technician Lamps cuts off sporadically Possible bad lamp or the fixture is overheating Lamp may be at the end of its...

Страница 14: ...10 nut on the rear end of the unit It has clear LEDs to show the DMX signal status of each output and input Universal DMX 512 optical splitter Additional thru output 3 pin and 5 pin for linking to oth...

Страница 15: ......

Отзывы: