Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 1.5 meter. 

 

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property ! 

 

 

Rigging

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the Cameleon Spot 18-4 Q4 is lowered from the ceiling or high joists, professional trussing systems 
have to be used. 

 

Use a clamp to mount the Cameleon Spot 18-4 Q4, with the mounting-bracket, to the trussing 
system. 

 

The Cameleon Spot 18-4 Q4 must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden.

 

 

 

 

 

The Cameleon Spot can be mounted in a hanging position (Fig. Above) or Upright (Fig. Below), using the 
support brackets. Mounting the Cameleon Spot with a clamp or any other mounting bracket is 
recommended, depending on the requirements of your application. 

 

 

 

 

The Cameleon Spot can be placed on a flat stage floor or mounted to any kind of truss by a clamp. 

 

Improper installation can cause serious damage to people and property !

 

 

Содержание Cameleon Spot 18-4 Q4

Страница 1: ...Cameleon Spot 18 4 Q4 ORDERCODE 42692...

Страница 2: ...esign and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant s...

Страница 3: ...Spot Built in Programs 8 Multiple Cameleon Spots Master Slave control 8 Multiple Cameleon Spots DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 DMX Control Mode 11 DMX Addressing 11...

Страница 4: ...conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of over...

Страница 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously...

Страница 6: ...es Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Cameleon Spot 18 4 Q4 is lowered from the ceiling or high joists profess...

Страница 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 8: ...ed IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave Manual Dimmer 0 100 Strobe 0 20Hz Bea...

Страница 9: ...7 Overview 1 2 Fig 1 1 Mountingbracket with adjustment screw 2 18x 4 in 1 4W RGBW LEDs Backside Fig 2 3 4 5 6 7 3 Power In 6 3 pin DMX Out 4 3 pin DMX In 7 Power Out 5 LCD Display Menu Buttons...

Страница 10: ...by a DMX cable it functions as a stand alone device Please see page 13 for more information about the Manual Color control One Cameleon Spot Built in Programs 1 Fasten the effect light onto firm trus...

Страница 11: ...e from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug the end of the mains power cord into pr...

Страница 12: ...er may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Cameleon Spots on a DMX data link 30 fixtures Data Cabling...

Страница 13: ...trol each Cameleon Spot correctly If two or more Cameleon Spots are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu d001 Contro...

Страница 14: ...12 Menu Overview 1 DMX Address 2 Manual Color 3 Auto Program 4 Built in Programs 5 Slave...

Страница 15: ...SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 4 Channel 6 Channels 8 Channels 2 Manual colors With this menu you can manually set a desired color 1 Pre...

Страница 16: ...Frequency from 00 99 Red 20 Green 80 Flash Frequency from 00 99 Green Flash Frequency from 00 99 Green Blue Flash Frequency from 00 99 Blue Flash Frequency from 00 99 Red 80 Blue 20 Flash Frequency fr...

Страница 17: ...Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 Channel 4 White 0 255 White gradual color brightness from 0 to 100 6 Channels Channel 1 Re...

Страница 18: ...4 color gradual change R G B W 54 80 Program 3 10 color gradual change 81 107 Program 4 4 color fantasy change 108 134 Program 5 4 color color switch R G B W 135 161 Program 6 10 color color switch 1...

Страница 19: ...c power supply cables must not show any damages or material fatigue Troubleshooting No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps b...

Страница 20: ...tion plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120...

Страница 21: ...owerconnector DMX Connection Dedicated IP65 connector Schuko to IP powercable included Lens Plate Tempered Glass Display LED display for auto and custom control Control DMX Auto Program Master slave M...

Страница 22: ......

Отзывы: