13
Order code: 34040
ACT Flood 80 RGBW
Control Panel
A)
OLED display
B)
ENTER button
C)
DOWN button
D)
UP button
E)
MENU button
Fig. 05
DMX Addressing
The control panel on the back side of the fixture allows you to assign the fixture a DMX address, which is
the first channel with which the ACT Flood will respond to a DMX controller.
When using multiple ACT Floods, make sure you set the DMX addresses right. The device has 11 channels.
Therefore, the DMX address of the first ACT Flood should be 1 (001); the DMX address of the second ACT
Flood should be 1+11=12 (012); the DMX address of the third ACT Flood should be 12+11=23 (023), etc.
Make sure that you do not have any overlapping channels in order to control each ACT Flood correctly.
If two or more ACT Floods are addressed similarly, they will work similarly.
Controlling:
After having addressed all ACT Floods, you may now start operating these via your lighting controller.
After switching on, the ACT Flood will automatically detect whether DMX 512-data is received or not. If
there is no data received at the DMX input, the problem may be:
●
The DMX cable from the controller is not connected with the input of the ACT Flood.
●
The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note: It is necessary to insert a termination plug (with 120 Ohm) in the last fixture in order to ensure proper
transmission on the DMX data link.