background image

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others! 
 
 

Rigging

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the FX Shot is lowered from the ceiling or high joists, professional trussing systems have to be 
used. 

 

Use a clamp to mount the FX Shot, with the mounting-bracket, to the trussing system. 

 

The FX Shot must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

Improper installation can cause serious damage to people and property !

 

 
 

Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place.

 

 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

PHASE 

BLUE 

BLACK 

SILVER 

NULL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 
 
 

 

Содержание 60908

Страница 1: ...FX Shot ORDERCODE 60908 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Страница 3: ...erminations 4 Rigging 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Accessories 7 Installation 8 Testing 10 Set Up and Operation 10 Disconnection 11 Maintenance 12 Troubleshooti...

Страница 4: ...perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused...

Страница 5: ...dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If...

Страница 6: ...n be carried out by an authorized dealer Procedure If the FX Shot is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the FX Shot with the mou...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...n 20 meters wide Suited for 40cm and 80cm shooters Plug and play Powersupply 240V 50 60 Hz Peak Power 100W Indoor use Operation 230V on off or DMX controlled by using a Multidim Multiswitch or Relay P...

Страница 9: ...ectric confetti and streamer cannons The FX Shot is not suitable for other than the 40 and 80mm cannons shown below 40cm Electric cannon 80cm Electric cannon Other confetti cannons The following types...

Страница 10: ...u cannot link multiple FX Shots together via IEC IN IEC OUT You have to connect them separately to AC power You can connect multiple shooters via one Schuko connection Schuko to 2 IEC splitter 90442 L...

Страница 11: ...inside the FX Shot it can be set to the correct shooting direction On the side of the FX Shot is a inclination screw which can be turned to position the holder in the right direction Never shoot direc...

Страница 12: ...ic cannon ignition connector into the input on top of the FX Shot This connector has a recess so that the plug can only be plugged into the socket one way ONLY connect the ignition plug when the blue...

Страница 13: ...nge The FX Shot may only be operated by adult and competent persons The FX Shot may only be operated when all components are completely and correctly installed connected Use caution when operating the...

Страница 14: ...it operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technician Response Suspect two potential problem areas the power supply or the...

Страница 15: ...50 60 Hz Peak Power 100W Indoor use Operation 230V on off or DMX controlled by using a Multidim Multiswitch or Relay Pack see p 9 11 FX Shot will be activated by a 230V power source and can therefore...

Страница 16: ......

Отзывы: